Emerson ROSEMOUNT 5300 Spécifications Page 61

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 106
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 60
Reference Manual
00809-0600-4026, Rev BA
December 2011
5-5
Rosemount Process Radar
Tri-Clamp Tank Connection
1. Place a gasket on top of the tank
flange.
2. Lower the transmitter and antenna into
the tank.
3. Fasten the Tri-Clamp to the tank with a
clamp.
4. To rotate the transmitter housing,
loosen the nut.
5. Rotate the transmitter housing so the
cable entries/display face the desired
direction.
6. Tighten the nut.
Bracket Mounting, on Wall
1. Mount the bracket directly to the wall
with screws suitable for the purpose.
2. Mount the transmitter with antenna to
the bracket and secure the installation
with the three supplied screws.
Bracket Mounting, on Pipe
1. Put the two U-bolts through the holes
of the bracket. Holes are available for
both vertical and horizontal pipe
mounting.
2. Put the clamping brackets on the
U-bolts and around the pipe.
3. Fasten the bracket to the pipe using
the four supplied nuts.
4. Mount the transmitter with antenna to
the bracket and secure with the three
supplied screws.
See the Rosemount 5400 Series Reference Manual
(Document No. 00809-0100-4026) for more installation details.
Gasket
Rod
antenna
Nut
Tank
connection
Tri-Clamp
Clamp
Transmitter
housing
Antenna
Bracket
U-bolts
Bracket
Antenna
Transmitter
housing
Clamping
Bracket
Vue de la page 60