Emerson FM-3 Guide de l'utilisateur Page 172

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 263
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 171
153
Diagnostics and Troubleshooting
Analog Output Source options are:
Velocity Command
Velocity Feedback
Torque Command (equates to Torque Command Actual parameter)
Torque Feedback
Following Error
Default Analog Output Source:
Channel 1 = Velocity Feedback
Channel 2 = Torque Command
Figure 111: Diagnostic Analog Output Test Points
The DGNE cable was designed to be used with either an oscilloscope or a meter. The wires
are different lengths to avoid shorting to each other. However, if signals do get shorted to
GND, the drive will not be damaged because the circuitry is protected.
Channel Output Source Offset Scale
1 Velocity Feedback 0 600 RPM/volt
2 Torque Command 0
30 percent/volt for selected
motor
Channel #2
Channel #1
Analog GND
E Series Drive
Epsilon Drive
Vue de la page 171
1 2 ... 167 168 169 170 171 172 173 174 175 176 177 ... 262 263

Commentaires sur ces manuels

Pas de commentaire