126
Epsilon Eb and EN Drives Reference Manual
Figure 105: Inputs Tab
To assign an Input Function to an Input line:
1. Assign an input by highlighting an input function in the "Input Functions" window and
selecting the desired input radio button or by dragging the highlighted input function to
the desired input in the "Input Lines" window.
2. To unassign an input function from an input line, select the desired input function from
the “Input Functions” window, then select the “Unassigned” radio button or by dragging
the highlighted input assignment back to the "Input Functions" window.
To make an Input Function “Active Off”:
1. Select the desired input function in the “Input Functions” window
2. Click the “Active Off” check box. The Active State column in the "Input Functions"
window will automatically update to the current setup.
To make an Input Function “Always Active”:
1. Select the desired input function in the “Input Functions” window.
2. Click the “Always Active” check box. The Active State column in the "Input Functions"
window will automatically update to the current setup.
Step 7: Assigning Outputs
Output functions are assigned in the Outputs tab which is divided into two windows. The
“Output Functions” window, on the left side, displays the output functions available. The