Emerson FM-3 Guide de dépannage Page 21

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 60
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 20
17
“u” “Low DC Bus Fault”
Reset with
Reset P/B
Operation
Returns To
Normal
Measure
AC Input
On Power Connector
Epsilon
"u" Fault
when using
Aux Power
Supply (+24VDC)
Use
PowerTools
to Disable
Monitoring
Open PowerTools
On Menu Bar
Click on
Options >
Preferences>General
Check Box
Select Advanced Tab
Go On Line
with the Drive,
In Detailed Mode
Select Advanced Tab
Uncheck Box by
Low DC Bus Enable
Reset with
Reset P/B
Operation
Returns To
Normal
"u" Fault
Low DC Bus
Yes
Segment 1
RSR-2 Malfunction
or
Improper Installation
Refer to RSR-2
Troubleshooting
Flowchart
Reapply Power
Rapid
Cycling of Power
Operation
Returns To
Normal
No
Yes
Yes
Segment 2
End
End
End
Segment 3
Remove Power
for 10 seconds
No
When Input AC returns
to 96 to 264 VAC
Reapply Power
Low Input AC
< 120 VAC &
Rapid DT with
Large Load
u Fault
Increase Input AC
> 120 VAC or
Increase AT
(
E-Series
)
24 VDC
APS
Disabled,
Low Bus
(
Epsilon
)
Segment 4
Operation
Returns To
Normal
End
Vue de la page 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 59 60

Commentaires sur ces manuels

Pas de commentaire