Emerson 3051S Spécifications Page 67

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 240
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 66
Reference Manual
00809-0200-4801, Rev CA
July 2010
5-1
Rosemount 3051S
Section 5 Troubleshooting
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5-1
Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5-1
Troubleshooting Guides . . . . . . . . . . . . . . . . . . . . . . . . . . page 5-2
Resource Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5-5
Sensor Transducer Block . . . . . . . . . . . . . . . . . . . . . . . . . page 5-6
Analog Input (AI) Function Block . . . . . . . . . . . . . . . . . . . page 5-7
LCD Transducer block . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5-8
Advanced Diagnostics Transducer Block (ADB) . . . . . . . page 5-9
PlantWeb Alerts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5-10
OVERVIEW This section provides summarized troubleshooting suggestions for the most
common operating problems. This section contains Rosemount 3051S
fieldbus troubleshooting information only. Disassembly and reassembly
procedures can be found in the 3051S manual, document 00809-0100-4801
located in the Troubleshooting.
Follow the procedures described here to verify that transmitter hardware and
process connections are in good working order. Always deal with the most
likely checkpoints first.
SAFETY MESSAGES Procedures and instructions in this section may require special precautions to
ensure the safety of the personnel performing the operations. Information that
raises potential safety issues is indicated by a warning symbol ( ). Refer to
the following safety messages before performing an operation preceded by
this symbol.
Warnings
Explosions can result in death or serious injury.
Do not remove the transmitter covers in explosive environments when the
circuit is live.
Transmitter covers must be fully engaged to meet explosion proof
requirements.
Before connecting a communicator in an explosive atmosphere, make sure
that the instruments in the loop are installed according to intrinsically safe or
nonincendive field wiring practices.
Static electricity can damage sensitive components.
Observe safe handling precautions for static-sensitive components.