Installation and Use Manual 31
Using ProLink II Software
ProLink II Setup Transmitter StartupUsing ProLink IIBefore You Begin
To enable inventory reset:
1. Choose
View > Preferences.
2. Select
Enable Inventory Totals Reset.
3. Click
Apply (if necessary).
To manage totalizers and inventories:
1. Choose
ProLink > Totalizer Control or ProLink > CM Totalizer Control (if the concentration
measurement application is enabled in the transmitter). See Figure 3-5.
2. Use the buttons in this window to start, stop, or reset the totalizers and/or inventories.
Note: The
Start, Stop, and Reset buttons displayed under All Totals affect the mass totalizer, the
volume totalizer, and all API-related totalizers.
3. The
Reset Inventories button under All Totals is displayed only if this function is enabled
(see above). Use this button to reset all inventories, including API-related inventories.
Note: ProLink II does not support separate resetting of the API volume totalizer and API volume
inventory. To reset these, you must reset all totalizers or all inventories.
Figure 3-5 Totalizer Control window