138
Reference Manual
00809-0200-4728, Rev RA
Appendix B: Product Certifications
April 2015
Product Certifications
Tables
Table B-1. Process Temperatures
Table B-2. Entity Parameters
T6 T5 T4 T3 T2 T1 T130
Max Ambient +40°C +60°C +60°C +60°C +60°C +60°C +70°C
Transmitter with LCD display
Sensor Extension
0” 55°C 70°C 95°C 95°C 95°C 95°C 95°C
3” 55°C 70°C 100°C 100°C 100°C 100°C 100°C
6” 60°C 70°C 100°C 100°C 100°C 100°C 100°C
9” 65°C 75°C 110°C 110°C 110°C 110°C 110°C
Transmitter without LCD display
0” 55°C 70°C 100°C 170°C 280°C 440°C 100°C
3” 55°C 70°C 110°C 190°C 300°C 450°C 110°C
6” 60°C 70°C 120°C 200°C 300°C 450°C 110°C
9” 65°C 75°C 130°C 200°C 300°C 450°C 120°C
Fieldbus/PROFIBUS HART 7 (Legacy) HART (Enhanced)
Voltage Ui (V) 30 30 30
Current Ii (mA) 300 200
150 for Ta ≤ 80 °C
170 for Ta ≤ 70 °C
190 for Ta ≤ 60 °C
Power Pi (W) 1.3 @ T4 (-50 °C ≤ Ta ≤+60 °C)
0.67 @ T6(-60 °C ≤ Ta ≤ +40 °C)
0.67 @ T5(-60 °C ≤ Ta ≤ +50 °C)
1.0 @ T5(-60 °C ≤ Ta ≤ +40 °C)
1.0 @ T4(-60 °C ≤ Ta ≤ +80 °C)
0.67 @ T6(-60 °C ≤ Ta ≤ +40 °C)
0.67 @ T5(-60 °C ≤ Ta ≤ +50 °C)
0.80 @ T5(-60 °C ≤ Ta ≤ +40 °C)
0.80 @ T4(-60 °C ≤ Ta ≤ +80 °C)
Capacitance Ci (nF) 2.1 10 3.3
Inductance Li (mH) 0 0 0