FRU Installation
AXP 1410 Installation and Use (6806800H70D)
69
Installation Procedure
To install a PEM, proceed as follows:
1. Screw a standoff/lockout screw extension onto the retaining screws located on
each side of the replacement PEM.
2. Align the back end of the replacement PEM with the rail guides in the empty PEM
slot and slide the PEM into the slot.
System Damage
Insufficient cooling can damage the system.
Lock the replacement PEM into the slot within 3 minutes to maintain the proper cooling
properties of the shelf.