Emerson 1410 Manuel de service Page 132

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 222
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 131
FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70D)
132
Hysteresis support Readable/Settable
Threshold access support Readable/Settable
Event message control Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3838 Critical and Non-Recoverable Thresholds
are Readable and Settable
Reading Type Unsigned
Critical and Non-Recoverable
thresholds
0x2D, 0x35, 0x3F (57, 67) Degrees C
Table 7-11 Sensor No. 34 FTM Temp 5
Feature Raw Value/Description Interpreted Value
Sensor Name FTM Temp 5
Device
Sensor Type 0x01 Temperature
Class 0x01 Threshold
Sensor Owner LUN 0x00
Entity ID 0x0A
Entity Instance 0x60
Rearm mode Auto
Hysteresis support Readable/Settable
Threshold access support Readable/Settable
Event message control Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3838 Critical and Non-Recoverable Thresholds
are Readable and Settable
Reading Type Unsigned
Critical and Non-Recoverable
thresholds
0x2D, 0x35, 0x3F (57, 67) Degrees C
Table 7-10 Sensor No. 33 FTM Temp 4 (continued)
Feature Raw Value/Description Interpreted Value