System Installation
AXP 1410 Installation and Use (6806800H70D)
49
Installation in a 19" Rack
To install a system in a 19" rack, proceed as follows:
1. Insert the system into a standard 19" ANSI rack.
2. Fasten the system to the rack via the mounting brackets using eight bolts or screws
(minimum 6 mm (0.24 inch) in diameter) on the left side and eight on the right side
of the system.
3. Make sure that the system has been located in a place with room temperature for
at least 24 hours before powering it up.
System Damage
During the course of handling, shipping, and assembly, pins, shrouds and mounting screws,
fans and other items can become loose or damaged.
Do not operate a damaged shelf, this can cause damage to devices that interfere with it.
Grounding
To ensure the system is properly grounded, each of the system's parts contact the EMI
gasket. The system contains gaskets at the shelf and module level.
The shelf is also fitted with ESD contacts. Please take care for proper ESD protection of the
operator.