Micro Motion
®
Series 3000 Transmitters and Controllers 5
Sensor cabling
Power supply
Requirements
(1)
(1) Model 3500/3700 only. Sensor cabling not applicable to Model 3300/3350.
With Sensor Interface Option 5:
Requires standard 4-wire twisted-pair shielded signal cable between the sensor and the
transmitter. Micro Motion recommends using Micro Motion 4-wire cable.
With Sensor Interface Option 6:
Requires standard 4-wire twisted-pair shielded signal cable between the transmitter and the
remote core processor. Micro Motion recommends using Micro Motion 4-wire cable.
Requires Micro Motion 9-wire signal cable between the remote core processor and the sensor.
Depending on the order, 10 feet (3 meters) of 4-wire cable or 10 feet (3 meters) of both 4-wire and
9-wire cable are shipped with the order. For longer cable lengths, contact Micro Motion.
Maximum cable lengths Cable type Wire gauge Maximum length
Micro Motion 9-wire Not applicable 60 feet (20 meters)
Micro Motion 4-wire Not applicable 1000 feet (300 meters)
User-supplied 4-wire
Power wires (VDC) 22 AWG (0.35 mm
2
) 300 feet (90 meters)
20 AWG (0.5 mm
2
) 500 feet (150 meters)
18 AWG (0.8 mm
2
) 1000 feet (300 meters)
Signal wires (RS-485) 22 AWG (0.35 mm
2
) or larger 1000 feet (300 meters)
AC power supply
Model 3300 85 to 265 VAC
50/60 Hz, 15 VA
0.25 A maximum at 85 VAC, 0.12 A maximum at 265 VAC
IEC 127-3/4 fuse, 0.63 A time-delay
Complies with European low-voltage directive 2006/95/EC per IEC 61010-1
Installation (Overvoltage) Category II, Pollution Degree 2
Models 3350, 3500,
and 3700
85 to 265 VAC
50/60 Hz, 30 VA
0.33 A maximum at 85 VAC, 0.15 A maximum at 265 VAC
IEC 127-3/4 fuse, 0.63 A time-delay
Complies with European low-voltage directive 2006/95/EC per IEC 61010-1
Installation (Overvoltage) Category II, Pollution Degree 2
DC power supply
Model 3300 18 to 30 VDC
7 watts typical, 14 watts maximum
IEC 127-3/4 fuse, 1.6 A time-delay
Models 3350, 3500,
and 3700
18 to 30 VDC
18 watts typical, 25 watts maximum
IEC 127-3/4 fuse, 1.6 A time-delay