Emerson ACE97 Manuel d'instructions

Naviguer en ligne ou télécharger Manuel d'instructions pour Autres dispositifs de saisie Emerson ACE97. Emerson ACE97 Instruction Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 32
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Type ACE97
D102773X012
Instruction Manual
Form 5665
November 2011
www.sherregulators.com
Type ACE97 Pad-Depad Valve
!
WARNING
Failure to follow these instructions or
to properly install and maintain this
equipment could result in an explosion,
re and/or chemical contamination
causing property damage and personal
injury or death.
Fisher
®
pad-depad valves must be
installed, operated, and maintained
in accordance with federal, state, and
local codes, rules and regulations,
and Emerson Process Management
Regulator Technologies, Inc. (Regulator
Technologies) instructions.
Figure 1. Type ACE97 Pad-Depad Valve (NPS 1/2 / DN 15 Pad Valve / 1 NPT Depad Valve Shown)
W8161
GAS INLET
ACTUATOR
PAD VALVE
TO TANK
DEPAD PILOT VALVE
DEPAD
MAIN
VALVE
VENT
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - Type ACE97 Pad-Depad Valve

Type ACE97D102773X012Instruction ManualForm 5665November 2011www.sherregulators.comType ACE97 Pad-Depad Valve!WARNINGFailure to follow these instruct

Page 2

Type ACE9710Table 5. Diagnostics Table: Cv 1 through 4, Inlet Pressure Range Spring 121 to 200 psig / 8,3 to 13,8 barACTUAL INLET SUPPLY PRESSURE TO

Page 3

Type ACE9711Table 9. Diagnostics Table: Cv 20 through 60, Inlet Pressure Range Spring 25 to 50 psig / 1,7 to 3,4 barACTUAL INLET SUPPLY PRESSURE TO V

Page 4

Type ACE9712are shown in Table 2. In order to evaluate a valve, examine the valve nameplate to determine the Cv and inlet pressure range (main valve

Page 5

Type ACE9713 2. Unthread the lower cage (key 110). 3. Remove the rain cap (key 109). 4. Unthread the upper cage (key 106). 5. Remove the retur

Page 6

Type ACE9714 5. Remove the plug (key 22) from the main valve. 6. Insert wooden dowel rod (or similar blunt tool) through the bottom of the bonnet

Page 7

Type ACE9715AssemblyBefore proceeding, read the following instructions. Refer to the gures that pertain to your valve (Figures 11 through 20) and rev

Page 8

Type ACE9716 3. Thread the poppet (key 42) onto the piston (key 37). Use soft-jawed pliers to restrain the piston so it is not damag

Page 9

Type ACE9717Actuator AssemblyRefer to Figure 20. 1. Place the actuator gasket (key 27) and lower actuator case (key 113) onto the body (key

Page 10 - Type ACE97

Type ACE9718Parts ListKey Description Part Number Parts Kits NPS 1/2 / DN 15 pad valve (includes keys 16, 27, 38, 39, and 41) Ni

Page 11

Type ACE9719 27 Gasket (bonnet, pad valve) GC070429X32 28 Lock Washer (28 required) GC060906X02 29 Hex-Head Machine Screw (4 required) NPS

Page 12

Type ACE972Pad (Tank Blanketing) Specications Pad Body Sizes and End Connection Styles1/2, 1, and 2 NPTNPS 1/2, 1, and 2 / DN 15, 25, and 50 CL150 R

Page 13

Type ACE9720 83 Seal Retaining Plate 1 NPT depad main valve GC053314X02 2 NPT depad main valve GC053311X02 NPS 3 / DN 80 depad main valv

Page 14

Type ACE9721 131 Tube Elbow (2 required) (external, 1/4-inch / 6,4 mm tube x 1/8 NPT) - - - - - - - - - - - 132 Tube Elbow (3 required) (ex

Page 15

Type ACE9722Figure 11. Type ACE97 Pad-Depad Valve ExteriorE0630NPS 1 / DN 25 PAD / 1 NPT DEPAD1311111311311431341571341421321311111311381291331491501

Page 16

Type ACE9723E0677Figure 12. Actuator Spring RangesPAD 0.5 TO 1.4 PSIG / 34 to 97 mbarDEPAD 0.25 TO 1 PSIG / 17 to 69 mbarPAD 1.0 TO 2.2 PSIG / 69 to

Page 17

Type ACE9724Figure 13. Type ACE97 NPS 1/2 / DN 15 Pad ValveE0631E063438523736394142145148182711329 2816165166

Page 18

Type ACE9725Figure 14. Type ACE97 NPS 1 / DN 25 Pad ValveGROOVE FOR ROLLING DIAPHRAGM BEADE063537363839404142351381834113E063227161726251924212223202

Page 19

Type ACE9726Figure 15. Type ACE97 NPS 2 / DN 50 Pad ValveGROOVE FOR ROLLING DIAPHRAGM BEAD3738394041423635113282916272649252423222120E063319 1851 52E

Page 20

Type ACE9727Figure 16. 1 NPT Depad Main ValveE06368076797881839187848613477828588759089143 135 131

Page 21

Type ACE9728Figure 17. 2 NPT Depad Main Valve E07058684838087134817679787791160161858275143135131

Page 22

Type ACE9729Figure 18. NPS 3 and 4 / DN 80 and 100 Depad Main Valve E067487758380134817679787715785847912614313513116016182

Page 23

Type ACE973If a leak develops or if the unit or outlet continually vents gas, service to the unit may be required. Failure to correct trouble could r

Page 24

Type ACE9730Figure 19. Depad Pilot Valve PartsE0675111ACTUATOR10910411031135100127131143108103102101106131120103107989913513110510438143135143

Page 25

Type ACE9731Figure 20. Actuator Parts113283193114931209998282911711827116949511916312128100E0676

Page 26

Type ACE97The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fishe

Page 27

Type ACE974Product DescriptionThe Type ACE97 Pad-Depad valve is a self-contained, pilot-operated valve that maintains a blanket of inert gas on top of

Page 28

Type ACE975NPS 1 and 2 / DN 25 and 50 Pad Valves (Figure 2)When tank pressure decreases below the pad setpoint (due to pump-out operations or thermal

Page 29

Type ACE976Installation and Startup!WARNINGPersonal injury, equipment damage, or leakage due to escaping accumulated gas or bursting of pressure-conta

Page 30

Type ACE977must agree with the system that you are Padding (blanketing) or Depadding (recovering). The serial number will be needed in any communicat

Page 31

Type ACE978Startup, Adjustment, and ShutdownCAUTIONIf required, tank vents (normal and emergency) must be in place and operating.StartupCAUTIONAlway

Page 32

Type ACE979Table 2. Diagnostic Analysis Pressure RangesDIAGNOSTIC STATUSEqual to inlet supply pressurePilot and main valves are closed. Tank pressur