Emerson Epsilon EiDeviceNet Drive Manuel d'utilisateur Page 63

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 96
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 62
51
Network Configuration Quick Start
Figure 19: Output Tab
After all of the data is mapped click OK, go online, and then download this RsNetworx file
to the DeviceNet scanner. (Make sure processor is in program mode.)
Note
If, after a download, errors occur on the DeviceNet Master (scanner card), clear all
mappings in the scanlist and download this “empty” file to the Master. The network
should display two green LED’s (if not check wiring... etc.). After this has occurred repeat
the above procedure to configure the Ei-DN onto the DeviceNet network.