Vue de la page 18
2-9
EN
Rosemount Inc
Multichannel Installations
You can connect several transmitters to a single master power supply, as shown in
Figure 2-8. In this case, the system may be grounded only at the negative power
supply terminal. In multichannel installations where several transmitters depend
on one power supply, and the loss of all transmitters would cause operational
problems, consider an uninterrupted power supply or a back-up battery. The
diodes shown prevent unwanted charging or discharging of the back-up battery.
Figure 2-8. Multichannel Installations
LCD Meter Installation
The LCD Meter for the 644H transmitter provides local indication of the
transmitter output and abbreviated diagnostic messages governing transmitter
operation. Transmitters ordered with the LCD meter are shipped with the meter
installed. After-market installation of the meter can be performed on Model 644H
transmitters that have a meter connector (transmitter Revision 5.5.2 or later).
After-market installation requires the meter kit (part number 00644-4430-0001),
which includes:
LCD meter assembly (includes LCD meter, meter spacer, and 2 screws)
Meter cover with O-ring in place
Figure 2-9. Installing the LCD Meter
Transmitter
No. 1
Transmitter
No. 2
R
Lead
R
Lead
R
Lead
Readout or
Controller
No. 1*
Readout or
Controller
No. 2*
To Additional
Transmitters
dc
Power
Supply
Backup
Battery
3044-0131A
*Between 250 and 1100 if no load resistor.
R
Lead
Model 644H
Captive Mounting Screws and Springs
Meter Spacer
LCD Meter
10 pin Connector