6 Micro Motion
®
Model 2400S Transmitters
Input/output signals
Model 2400S Analog
Channel A One active or passive 4–20 mA output
• Not intrinsically safe
• Isolated to ±50 VDC from all other outputs and earth ground
• Maximum load limit: 820 ohms
• External (passive) power: 12 to 30 VDC, 24 VDC typical
• Can report mass flow, volume flow, density, temperature, or drive gain
• Output is linear with process from 3.8 to 20.5 mA, per NAMUR NE43 (February 2003)
Channel B (configurable) One active or passive frequency/pulse output
• Not intrinsically safe
• Can report mass flow or volume flow, which can be used to indicate flow rate or total
• Scalable to 10,000 Hz
•Power:
- Internal (active): +24 VDC ±3% with a 2.2 kohm internal pull-up resistor
- External (passive): +30 VDC maximum, +24 VDC typical
• Output is linear with flow rate to 12,500 Hz
One active or passive discrete output
• Not intrinsically safe
• Can report five discrete events, flow switch, forward/reverse flow, calibration in progress,
or fault
•Power:
- Internal (active): +24 VDC ±3% with a 2.2 kohm internal pull-up resistor
- External (passive): +30 VDC maximum, +24 VDC typical
• Maximum sink capability: 500 mA
One active or passive discrete input
• Not intrinsically safe
•Power:
- Internal (active): +24 VDC, 10 mA maximum source current
- External (passive): +3 to 30 VDC maximum
• Can reset all totals, reset mass total, reset volume total, start/stop totals, or start sensor
zero
Model 2400S PROFIBUS-DP Digital 2-way PROFIBUS-DP signal.
Certified by Profibus User Organization (PNO).
Model 2400S DeviceNet Digital 2-way DeviceNet signal.
Certified by Open DeviceNet Vendor Association (ODVA).