29
Installation
Figure 29: Master/Slave Encoder Connections
Note
Epsilon encoder outputs meet RS-422 driver specifications and can drive up to 10 RS-422
signal recievers. Each Epsilon differential pulse input is an RS-422 line recievers. The
default encoder output resolution is 2048 lines per motor revolution. This resolution is
adjustable in one line per revolution increments with PowerTools software. The range is
between 200 and the actual motor encoder density.