Vue de la page 0
www.Fisher.com
Fisher
r
FIELDVUE
DLC3020f Digital Level
Controller for F
OUNDATION
fieldbus
Contents
Installation 3.....................
Mounting 10......................
Electrical Connections 14...........
Configuration 18..................
Calibration 33.....................
Nameplates and Schematics 37......
Specifications 41..................
Note
This quick start guide provides installation and initial setup and calibration information for the DLC3020f digital level controller
using AMS Suite: Intelligent Device Manager.
Quick Start Guide
D103470X012
DLC3020f Digital Level Controller
July 2012
This quick start guide applies to:
3020
1
1.0
1.0
0x03
Device Type
Device Revision
Hardware Revision
Firmware Revision
DD Revision
Vue de la page 0
1 2 3 4 5 6 ... 47 48

Résumé du contenu

Page 1 - fieldbus

www.Fisher.comFisherr FIELDVUE™ DLC3020f Digital LevelController for FOUNDATION™ fieldbusContentsInstallation 3...Mounting 10...

Page 2

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201210Mounting WARNINGTo avoid personal injury or property damage, always wear prot

Page 3 - Installation

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201211The DLC3020f digital level controller is typically shipped attached to the sen

Page 4 - Lever Lock

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 20121282463715SENSORCAGEDCAGELESSRIGHT‐OF‐DISPLACERLEFT‐OF‐DISPLACER1 NOT AVAILA

Page 5

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201213HEAT INSULATORREQUIRED700 20 40 60 80 100 120 140 160010 20-20 -1030 40 50 604

Page 6

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 2012146. Carefully slide the digital level controller with the attached insulator o

Page 7

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 2012151. Remove the terminal box cover (key 6) from the terminal box (key 5).2. Br

Page 8

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201216Communication Connections WARNINGPersonal injury or property damage caused by

Page 9

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201217nConfiguration and Calibration Check ListConfiguration and Calibration complet

Page 10 - Mounting

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201218ConfigurationNoteThis quick start guide documents procedures in AMS Device Man

Page 11 - DLC3020f Orientation

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201219GUIDED SETUPINSTRUMENT SETUPCONFIGUREFigure 10. Guided SetupManual SetupAMS De

Page 12

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 20122nInstallation Check ListInstrument correctly configured and mounted on the sens

Page 13 - DIGITAL LEVEL CONTROLLER

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201220CONFIGUREMANUAL SETUPDEVICE TABSELECT UNIT SYSTEMSENSOR PARAMETERSVARIABLECONF

Page 14 - Electrical Connections

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201221Sensor UnitsSelect the appropriate sensor units for your application.NoteDefau

Page 15 - WARNING

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201222NoteTable 5 provides the driver rod length of 249 sensors with vertical displa

Page 16 - Communication Connections

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201223HORIZONTAL CLOF TORQUE TUBEVERTICAL CL OF DISPLACERDISPLACER ROD LENGTHVESSELF

Page 17 - July 2012

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201224Process FluidSelect the Process Fluid tab (figure 14) to access Process Fluid,

Page 18 - Configuration

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201225Temperature CompensationIf Temperature Compensation is selected, provide the f

Page 19 - Manual Setup

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201226Decimal PlacesEnter the number of desired decimal places for the device displa

Page 20 - Sensor Hardware Information

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201227Primary ValuePV in engineering unitsPrimary Value PercentPV in %DI1 Trip Point

Page 21 - Sensor Parameters

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201228MANUAL SETUPOPTIONS TABMODEWRITE ALARMCONFIGURERESOURCE BLOCKTRANSDUCER BLOCKA

Page 22 - Table 5. Driver Rod Length

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201229Confirm TimeConfirm Time determines the time in 1/32 of a millisecond, the ins

Page 23 - Torque Tube

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 20123InstallationDo not install, operate, or maintain a DLC3020f digital level contr

Page 24 - Process Fluid

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201230Features SelectedNoteTypically this parameter does not need to be changed. The

Page 25 - Instrument Display

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201231ALERT SETUPOPERATIONALALERT SETUP TABCONFIGUREELECTRONICSRATE LIMITSCROLL DOWN

Page 26 - Snap Acting Control

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201232Maintenance— indicates a problem with the DLC3020f that, if ignored, could eve

Page 27 - Write Alarm

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201233D Hall Sensor— when selected indicates if the Hall Sensor readings are out of

Page 28 - Write Lock

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201234Calibrate InstrumentChoose Full Calibration (Bench) or Full Calibration (Field

Page 29 - Function Block Available

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201235EXPERT USERCALIBRATIONS TABFULL CALIBRATIONTRIM CURRENT CALIBRATIONCONFIGURECA

Page 30 - Alert Setup

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201236When complete, the torque rate or gain will be correct at the calibration temp

Page 31 - PlantWeb Alerts

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201237Schematics and NameplatesThis section includes loop schematics required for wi

Page 32 - Sensor Board

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201238 THE ENTITY CONCEPT ALLOWS INTERCONNECTION OF INTRINSICALLY SAFE APPARATUS TO

Page 33 - Calibrate

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201239REFER TO FIGURE 25 FOR NOTESFigure 24. FM Schematic (Refer to figure 25 for No

Page 34 - Expert User Calibrations

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 20124Protecting the Coupling and FlexuresCAUTIONDamage to flexures and other parts c

Page 35 - Calibration Descriptions

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201240Figure 25. FM Schematics (Notes) THE ENTITY CONCEPT ALLOWS INTERCONNECTION OF

Page 36 - Trim Current Calibration

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201241Instrument DescriptionThe FIELDVUE DLC3020f digital level controller (figure 2

Page 37 - Schematics and Nameplates

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201242Related DocumentsOther documents containing information related to the DLC3020

Page 38

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201243Table 6. SpecificationsAvailable ConfigurationsMounts on 249 caged and cageles

Page 39

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201244Table 6. Specifications (continued)Alerts and DiagnosticsElectronic Alerts adv

Page 40

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201245Table 7. FIELDVUE DLC3020f EMC Summary Results—ImmunityPort Phenomenon Basic S

Page 41 - Specifications

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201246Table 10. Displacer and Torque Tube MaterialsPart Standard Material Other Mate

Page 42 - Educational Services

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201247Table 12. Cageless Displacer Sensors(1)Mounting SensorStandard Head(2),Wafer B

Page 43 - -continued

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201248Emerson Process Management Marshalltown, Iowa 50158 USASorocaba, 18087 BrazilC

Page 44

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201252. If the displacer cannot be blocked because of cage configuration or other c

Page 45 - JReflex gauges for

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 20126Hazardous Area Classifications and Special Instructions for “Safe Use” andInsta

Page 46

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 20127FMIntrinsically Safe, Explosion‐proof, Non-Incendive, Dust Ignition‐proofNo spe

Page 47

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 20128ATEXSpecial Conditions for Safe UseIntrinsically Safe & DustThis apparatus

Page 48

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 20129IECExConditions of CertificationIntrinsically Safe & DustThis apparatus sha