Page 1 - ZX Platform Condensing Unit

ZX Platform Condensing Unit User Manual

Page 2

7Electrical ConnectionPower supply The ZX condensing unit electrical connection to the power supply must be made by qualified technicians, who should

Page 3

8ZX Platform Condensing Unit Refrigeration connections Refrigeration piping installation All interconnecting pipes should be of refrigeration grade, c

Page 4 - ZX Platform CDU

9Location and fixing The unit should always be installed in a location that ensures clean air flow. It is recommended that a clearance of 300 mm from

Page 5 - - “ACC” indicates accessory

10ZX Platform Condensing Unit Start Up and Operation(1 second)->- Power On- Unit Identification Code- Software Version No.(3 seconds)->(3 second

Page 6 - Physical Layout

11Alarm messaging - Digital scroll controller (ZXD)Alarm Mode Set Points Controller Actions Reset RemarksdtLDLT >= dtL after dLd time delay- Compre

Page 7 - Product Specication

12ZX Platform Condensing Unit BLUEZX Condensing Unit Wiring DiagramPFJ: 220V-50 Hz -1Ph ATTENTION: Unit MUST be grounded!

Page 8

135.Only ZXL TF5 has 4 additional posts on the terminal block.ZX/ZXL Condensing Unit Wiring DiagramTFD: 380V/420V -50 Hz-3PhTF7: 380V-60 Hz -3PhATTENT

Page 9 - Figure 06

14ZX Platform Condensing Unit ZX/ZXL Condensing Unit Wiring DiagramTF5: 200/230V- 50 Hz/ 60 Hz - 3PhATTENTION: Unit MUST be grounded!

Page 10 - Installation

15ZXD Condensing Unit Wiring Diagram (With Fan Speed Control Function)TFD - 380/420V, 50Hz, 3PhTF7 - 380V, 60Hz, 3Ph052-2662-002012-02-159 11 N10 NNTe

Page 11

16ZX Platform Condensing Unit ZXD Condensing Unit Wiring Diagram (Without Fan Speed Control Function)TFD - 380/420V, 50Hz, 3PhTF7 - 380V, 60Hz, 3Ph052

Page 13

Asia 02 A01 10 – R00 Issued 4/2012Emerson, Copeland PerformanceAlert and Copeland Scroll are trademarks of Emerson Electric Co. or one of its afliate

Page 14 - (ZX-MT and ZXL-LT)

Index Disclaimer...

Page 15

1ZX Platform CDUDisclaimer Thank you for purchasing the ZX platform condensing unit from Emerson Climate Technologies. ZX platform CDUs are the best i

Page 16 - TF7: 380V-60 Hz -3Ph

2ZX Platform Condensing Unit Proprietary Electronic Algorithms to Control Fan Speed, Optimizing Energy Performance for Local Seasonal Ambient Temperat

Page 17

3Physical LayoutThe following figures give an introduction to the physical layout of the ZX Platform CDU.ZX- MT, ZXL-LT E2 Controller* ZXD Digital Scr

Page 18 - Controller

4ZX Platform Condensing Unit ZX ZXD ZXLModel BOM Model BOM Model BOM401 451 ALL ALLZX0200/E1.181.68ZXL0200/E 1.06ZX0250/E1.331.83ZXL0250/E 1.06ZX0

Page 19

5E2 Control Board - Rotary Switch And Dip Switch Setting (ZX-MT & ZXL-LT)ModelRotary Switch3-Bit No. 32-Bit 1/2ZX0200/E-PFJ 7 OFF ON/ONZX0250/E-PF

Page 20 - EmersonClimate.com/Asia

6ZX Platform Condensing Unit Digital Scroll controller (ZXD)The controller has been pre-programmed with a number of parameter values that are set for