Step 8. Install hardware to secure new vibration isolators (5) to mounting holes of Vission 20/20
microcontroller (6).
Figure 3. Vission 20/20 with Vibration Isolators
Step 10. With additional personnel or lifting device, install hardware to secure Vission 20/20 microcontroller (6)
with vibration isolators (5) to rails (3).
NOTE
Ensure to use correct transducers because transducers have different pressure
ranges. Suction manifold uses 0-200 psia transducer, discharge manifold and oil
lter inlet uses 0-414.5 psia transducer.
Step 9. Install transducers (7) on block and bleed assembly (4).
Figure 4. Block and Bleed Assembly with Transducers