The Specications section on this page provides the ratings and other specications for the Type MR105. The
following information is stamped on the nameplate fastened on the regulator at the factory: type; body size;
maximum inlet, outlet and differential pressure; maximum pressure above setpoint; maximum casing pressure;
maximum temperature; spring range; cage type; and trim and diaphragm material.
Body Sizes and End Connection Styles
See Table 1

Class VI (Soft Seat)
Maximum Inlet, Outlet and Emergency
Casing Pressures
(1)
See Table 3
Outlet Pressure Ranges
(1)
5 to 300 psig / 0.34 to 20.7 bar; see Table 2
Maximum Setpoint
(1)
Low-Pressure Actuator: 43 psig / 3.0 bar
High-Pressure Actuator:
Nitrile (NBR) and Ethylene Propylene (EPDM)
Diaphragm: 300 psig / 20.7 bar
Fluorocarbon (FKM) Diaphragm: 150 psig /
10.3 bar
Maximum Pressure Over Setpoint to Avoid Internal
Parts Damage
(1)
Low-Pressure Actuator: 20 psig / 1.4 bar
High-Pressure Actuator: 120 psig / 8.3 bar
Maximum Differential Pressures
(1)
See Table 4
Temperature Capabilities
(1)
Nitrile (NBR): -20 to 180°F / -29 to 82°C
Fluorocarbon (FKM)

: 20 to 250°F / -7 to 121°C
Ethylene Propylene (EPDM)

: -20 to 225°F /
-29 to 107°C

See Table 5
Pressure Registration
External
Downstream Control Line Connection Size
1/2 NPT
Spring Case Vent
Type Y602-12
Pressure-Loaded Spring Case Vent
1/2 NPT
Approximate Weights
For Type MR105 with Low-Pressure Actuator
NPS 1 / DN 25 : 86 lbs / 39 kg
NPS 2 / DN 50: 116 lbs / 53 kg
NPS 3 / DN 80: 165 lbs / 75 kg
NPS 4 / DN 100: 174 lbs / 79 kg
For Type MR105 with High-Pressure Actuator
NPS 1 / DN 25: 76 lbs / 34 kg
NPS 2 / DN 50: 105 lbs / 48 kg
NPS 3 / DN 80: 155 lbs / 70 kg
NPS 4 / DN 100: 164 lbs / 74 kg
Options
Visual Travel Indicator
Drain Valve
Pressure-Loaded Actuator
NACE Construction
Bleed Valve (for High-Pressure Actuator Only)
Ethylene Propylene (EPDM) Elastomer
Trim Parts
1. The pressure/temperature limits in this Instruction Manual and any applicable standard or code limitation should not be exceeded.
2. Fluorocarbon (FKM) is limited to 200°F / 93°C in hot water.
3. Ethylene Propylene (EPDM) is limited to 20 to 250°F / -7 to 121°C when used with Low Pressure Actuator.
Introduction
Scope of the Manual
This instruction manual provides installation,
adjustment, maintenance and parts ordering
information for Type MR105 direct-operated
pressure reducing regulators.
Description
The Type MR105 direct-operated pressure reducing
regulators are high capacity multi-purpose regulators.
They are designed to handle pressures up to 400 psig /
!
WARNING
To avoid possible personal injury,
equipment damage or leakage due to

an external load to the actuator or any
part of the regulator while working
around the regulator.
Note
To avoid cavitation, it is recommended that
the customer follow the capacity sizing

Vue de la page 1