The Liebert FPC
A Proven System
The packaged system approach of the Liebert FPC is convenient and space-saving,
reducing installation time and cost compared to a conventional approach using multiple
interconnected components. The Liebert FPC is built on a proven system design used in
thousands of installations, and unlike one-of-a-kind, built-up distribution arrangements
constructed at the site, it undergoes thorough factory testing as a complete system to
assure reliable, consistent performance.
There are a number of integral features that enable the Liebert FPC to offer a higher
quality level of electrical power for your critical applications:
The Liebert FPC is designed to bring you a distribution system that will close
the power delivery loop in your critical IT operations.
The Liebert FPC features a compact, space saving design, exible breaker congurations,
plus local and remote power monitoring capabilities. Available in capacities from 15
kVA up to a new 300 kVA system, the Liebert FPC offers exibility to t both the space
and electrical requirements of IT equipment. Other features and enhancements make
Liebert FPC the right choice to protect sensitive electronics in growing sites.
Input Breaker
Accuvar Surge
Supression Module
Optional Features Include:
Remote emergency power off
(EPO) switch.
Subfeed breakers, up to three
225A or 400A on 150-300 kVA.
Square D bolt-in or plug-in
inline panelboards.
GE bolt-in or plug-in inline
panelboards.
Low voltage control junction
box with cable.
Lightning/surge arrester.
Output surge suppression
module.
Liebert Accuvar transient
voltage surge suppressor.
K-factor transformer.
Isolated ground bus bars.
22kAIC panelboard mains.
EZ-View or solid doors.
Side panels.
Liebert Distribution
Monitoring.
Computer-Grade Grounding — The
Liebert FPC automatically establishes
a single point ground to meet major
manufacturers’ recommendations
and the requirements of the National
Electric Code.
Handles Non-Linear Loads — Fully
compatible with the non-linear loads of
modern computer systems and other
electronic equipment.
Main Input Breaker With Shunt Trip
— provides primary transformer
overcurrent protection, a power
disconnecting means and a method to
interface with shutdown controls.
Double-Shielded TP-1 Listed Isolation
Transformer — provides higher
efciency than standard transformers
plus quieter operation.
One Or More Individually Enclosed 42-
Pole Output Panelboards — with main
breaker and individual isolated neutral
and ground bus bars distribute power to
the sensitive load equipment.
Monitoring — Built-in metering
and alarm annunciation with
communication to Liebert centralized
monitoring.
Space Savings — Compact single cabinet
conserves valuable oor space.
Easy Installation — Single input cable
connection reduces installation time
and cost.
Full Front And Rear Access — with
removable doors and panels, bottom or
top cable entry/exit.
Location Flexibility — The unit can
be easily relocated to protect your
investment.
UL and ULc Listed as a Complete System
— Meets safety requirements for fast,
hassle-free inspection and building code
approvals.