Types EZH and EZHSO
13
Figure 14. Working Monitoring System Operational Schematic with Two EZH (Spring-to-Close) for DN 25, 50, and 80
R100
V
S
L
A
A
B
S
S
L
L
B
B
V
R
R
M
M
R1
R2
TYPE SA/2
TYPE SA/2
TYPE PRX/125
TYPE PRX/120
TYPE PRX/120
TYPE EZH TYPE EZH
Inlet pressure (Pu)
Outlet pressure (Pd)
Motorization pressure (Pm)
Pilot feeding pressure (Pup)
Atmospheric pressure (Pb)
The schematic from Figure 14 represents the conguration for
the DN 25, 50, and 80, for the DN 100 the schematic remains
the same with the remark that a check valve (Figure 26) must
be installed between outlet pressure and loading pressure
impulse lines of the regulator and working monitor as well.
INSTALLATION
!
WARNING
Personal injury or equipment damage, due
to bursting of pressure-containing parts may
result if this regulator is overpressured or
is installed where service conditions could
exceed the limits given in the characteristics
section and on the appropriate nameplate,
or where conditions exceed any rating of
the adjacent piping or piping connections.
To avoid such injury or damage, provide
pressure-relieving or pressure-limiting
devices to prevent service conditions
from exceeding those limits. Also, be sure
that installation is in compliance with all
applicable code and regulations.
Physical damage to the regulator can break
the pilot off the main valve, causing personal
injury and property damage due to bursting
of pressure-containing parts. To avoid such
injury and damage, install the regulator in a
safe location.
Only personnel qualied through training
and experience should install, operate, and
maintain a regulator.
Before installation, make sure that there is no
damage to, or debris in the regulator.
Make sure that all tubing and piping are clean
and unobstructed.
The regulator must be installed on
horizontal pipeline. For the version with
slam shut, the release relay must be
situated towards the bottom.
Installation according to EN 12186
is recommended.
When assembling with adjacent elements
take care not to create pressure force on
the body. The assembling elements (bolts,
O-rings, anges) should be compatible with
the geometry and working conditions of the
equipment. If the case arises a support must
be used to avoid pressure force on the body
(a support can be installed under the anges).
TYPE PRX:
S - BLEED PORT TYPE SA/2
B - SUPPLY PORT V - SENSING
L - MOTORIZATION PORT R - PILOT
A - SENSING PORT M - INLET