Gas flow performance
When selecting sensors for gas applications, measurement accuracy is a function of fluid mass flow rate independent of operating
temperature, pressure, or composition. However, pressure drop through the sensor is dependent upon operating temperature,
pressure, and fluid composition. Therefore, when selecting a sensor for any particular gas application, it is highly recommended
that each sensor be sized using the Micro Motion product selector, available at www.micromotion.com.
Mass Volume
(1)
(1) Normal (Nm
3
/h) reference conditions are 1,013 bar and 0 °C.
kg/h Nm
3
/h
Flow rates that produce approximately 0,68 bar pressure drop on air at 20 °C and 6,8 bar
CMF025 110 90
CMF050 300 230
CMF100 1300 1000
CMF200 4000 3100
Flow rates that produce approximately 3,4 bar pressure drop on natural gas (MW 16,675) at 20 °C and 34,0 bar
CMF025 450 600
CMF050 1140 1530
CMF100 5000 6700
CMF200 15200 20500
Mass flow accuracy
(2)
(2) Flow accuracy includes the combined effects of repeatability, linearity, and hysteresis.
±0,35% of rate
(3)
(3) When flow rate is less than zero stability / 0,0035, accuracy equals ±[(zero stability / flow rate) × 100]% of rate and repeatability
equals ±[½(zero stability / flow rate) × 100]% of rate.
Mass flow repeatability ±0,20% of rate
(3)
Zero stability Refer to liquid flow specifications on page 3.