Vue de la page 0
Monitoring
For Business-Critical Continuity™
Liebert
®
IntelliSlot
®
Web Cards
Installation Manual – Liebert IntelliSlot Web Card, Liebert IntelliSlot Web Card-LB,
Liebert IntelliSlot Web Card-LBDS, Liebert IntelliSlot Web/485 Card-ADPT
Vue de la page 0
1 2 3 4 5 6 ... 59 60

Résumé du contenu

Page 1 - Web Cards

MonitoringFor Business-Critical Continuity™Liebert® IntelliSlot® Web CardsInstallation Manual – Liebert IntelliSlot Web Card, Liebert IntelliSlot Web

Page 2

Configuration Overview63.0 CONFIGURATION OVERVIEWYou may use any of the following interfaces to configure the Web card: Each configuration section pro

Page 3 - TABLE OF CONTENTS

Configuration Overview73.2 Open the Terminal Emulation Interface - Serial ConnectionTo access configuration using terminal emulation software with a s

Page 4

Configuration Overview83.3 Open the Terminal Emulation Interface - TCP/IP ConnectionTo access configuration using terminal emulation software with an

Page 5 - SAVE THESE INSTRUCTIONS

Configuration Overview93.4 Open the Telnet InterfaceTo access configuration using Telnet:1. Open a Telnet connection on a computer with an Ethernet co

Page 6 - 1.0 INTRODUCTION

Configuration Overview103.5 Open the Web InterfaceTo access configuration using the Web interface:1. Open a Web browser such as Internet Explorer, the

Page 7 - Introduction

System Information114.0 SYSTEM INFORMATIONSystem Information is optional and identifies the Liebert unit, its location, a contact person and other inf

Page 8 - 2.0 INSTALLATION

Network Settings125.0 NETWORK SETTINGSThe IP Network Settings Menu is used to enable network communications with the Web card.Refer to the following s

Page 9 - 2.2.1 Connect the Cable

Network Settings135.1 Boot/IP SettingsThe Boot/IP Settings Menu is used to set parameters for network access to the Web card. Consult your network adm

Page 10 - 3.0 CONFIGURATION OVERVIEW

Network Settings145.2 Domain Name Server (DNS) SettingsThe Domain Name Server settings menu configures the servers the Web card will use for hostname

Page 11

Network Settings15Web InterfaceTo access the DNS menu through the Web interface:• Click on the Configure tab, then Network Settings in the left panel

Page 13 - 3.4 Open the Telnet Interface

Network Settings16Web InterfaceTo access Management Protocol settings through the Web interface: • Click on the Configure tab, then Management Protoco

Page 14 - 3.5 Open the Web Interface

Network Settings17SNMP Communications MenuUse the SNMP Communications Menu to enable authentication traps and view or change communi-ties and trap com

Page 15 - 4.0 SYSTEM INFORMATION

Network Settings18Display/Modify Trap CommunitiesView devices that are configured to receive notifications from the Web card, identified by IP address

Page 16 - 5.0 NETWORK SETTINGS

Network Settings195.4 Web ServerUse the Web Server Menu to configure access to the card through the Web interface. Consult your network adminis-trator

Page 17 - 5.1 Boot/IP Settings

Network Settings205.4.2 Install Security Certificates - Internet Explorer 6 or earlierIf you use Internet Explorer 6 or an earlier version and select

Page 18

Network Settings21• In the Certificate window, click the Install Certificate button, as shown below.• The Certificate Import Wizard opens. Click Next.

Page 19 - 5.3 Management Protocol

Network Settings225.4.3 Install Security Certificates - Internet Explorer 7 or laterIf you use Internet Explorer 7 or later and select HTTPS as the op

Page 20 - Web Interface

Network Settings23• In the Certificate window, click the Install Certificate button, as shown below.• The Certificate Import Wizard opens. Click Next.

Page 21 - Display/Modify Communities

Network Settings245.5 Telnet ServerUse the Telnet Server Menu to enable or disable access to the Web card through a Telnet interface.Terminal Emulatio

Page 22

Network Settings25Terminal Emulation (Serial or TCP/IP Connection) / TelnetTo change this setting:1. Choose IP Network Settings from the Main Menu, th

Page 23 - 5.4 Web Server

iTABLE OF CONTENTSIMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.0 IN

Page 24

Network Settings265.7 Change Username / PasswordThe Web card is designed for two types of access, each with a default user name and password. For secu

Page 25

Network Settings275.8 Reset Authentication to Factory DefaultsYou may reset the Administrator and General User usernames and passwords to the factory

Page 26

Messaging286.0 MESSAGINGThe Messaging menu is used to set up e-mail and text message notifications from the Web card.Terminal Emulation (Serial or TCP

Page 27

Messaging296.1 E-Mail ConfigurationSetting up event notifications to be sent via e-mail involves two steps: enabling the function, then specifying the

Page 28 - 5.6 Time (SNTP) Menu

Messaging30Web InterfaceTo access E-Mail Configuration through the Web interface:• Click on the Configure tab, then Email in the left panel and finall

Page 29

Messaging31Terminal Emulation (Serial or TCP/IP Connection) / TelnetTo activate and set up SMS messages:1. Choose Messaging from the Main Menu, then S

Page 30

Messaging326.3 Customize MessagesBoth e-mail and SMS text messages may be custom-ized to include items such as the IP address or host-name, event name

Page 31

Messaging33Web InterfaceTo access Customize Message settings through the Web interface:• Click on the Configure tab, then Customize Messages in the le

Page 32 - 6.0 MESSAGING

Factory Settings347.0 FACTORY SETTINGSFactory default values may be restored for all configuration settings. This step:• Replaces all user-defined set

Page 33 - 6.1 E-Mail Configuration

Factory Settings357.2 Liebert DS - Local Node Settings for Multiple CardsIf you use two cards of the same type with the Liebert DS, you will need to c

Page 34 - 6.2 SMS Configuration

ii9.0 SUPPORT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .399.1 View Web Card Infor

Page 35 - Enable SMS [y/n] ?>

Monitor and Control Functions - Web Only368.0 MONITOR AND CONTROL FUNCTIONS - WEB ONLYWeb Interface OnlyThe Web interface allows you to monitor and co

Page 36 - 6.3 Customize Messages

Monitor and Control Functions - Web Only378.2 Controlling Liebert EquipmentTo perform Control operations through the Web interface:• Open the Web inte

Page 37

Monitor and Control Functions - Web Only388.3 Event LogThe Event Log tab allows viewing events stored in the Web card’s history. This history is gathe

Page 38 - 7.0 FACTORY SETTINGS

Support Information399.0 SUPPORT INFORMATIONSupport data includes identifying information for the Web card, as well as events and parameters available

Page 39

Support Information409.2 Events and ParametersYou may view a list of all supported events and parameters for the Liebert equipment through any interfa

Page 40 - Web Interface Only

IntroductionA1APPENDIX A-FIRMWARE UPDATESA.1 INTRODUCTIONLiebert’s IntelliSlot® cards may be updated to take advantage of the latest release of the fi

Page 41

Connect to the Card - Terminal Emulation, Telnet or Web InterfaceA2A.2 CONNECT TO THE CARD - TERMINAL EMULATION, TELNET OR WEB INTERFACEUpgrading the

Page 42 - 8.3 Event Log

Preparing to Update Liebert IntelliSlot FirmwareA3A.2.3 Open the Telnet InterfaceTo connect to the card using Telnet:1. Open a Telnet connection on a

Page 43 - 9.0 SUPPORT INFORMATION

Preparing to Update Liebert IntelliSlot FirmwareA4A.3.2 Determine the Liebert IntelliSlot Card Type and Firmware VersionEach type of Liebert IntelliSl

Page 44 - 9.2 Events and Parameters

Updating the Firmware - HTTP (Web) MethodA5A.3.4 Choose a Method to Install the Firmware UpgradeTo install the firmware upgrade, choose one of these t

Page 45 - A.1 INTRODUCTION

1IMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONS!WARNINGOnly a qualified service professional should install these products. Liebert recommends h

Page 46 - Password: ********

Updating the Firmware - TFTP (HyperTerminal, Telnet, Web) MethodA6A.5 UPDATING THE FIRMWARE - TFTP (HYPERTERMINAL, TELNET, WEB) METHODFollow these ste

Page 47 - A.2.4 Open the Web Interface

Updating the Firmware - TFTP (HyperTerminal, Telnet, Web) MethodA7Begin the Upgrade Process11. When ready to begin the update, choose Initiate TFTP Fi

Page 48

Updating the Firmware - TFTP (HyperTerminal, Telnet, Web) MethodA8Specify TFTP Server and Upgrade Filename4. Click the Edit button in the right panel.

Page 49

Updating the Firmware - Xmodem (Serial) MethodA911. During the update, the window displays a progress bar, as shown below left.After the firmware upda

Page 50 - Reconnect to the Card

Updating the Firmware - Xmodem (Serial) MethodA10Connect a Cable to the Serial Ports1. Connect one end of a DB-9 null modem or file transfer cable to

Page 51 - Begin the Upgrade Process

Updating the Firmware - Xmodem (Serial) MethodA11Download the First Firmware Update File12. After changing the communication rate to 115200 bps, press

Page 52

Updating the Firmware - Xmodem (Serial) MethodA12Complete the Upgrade and Restore Communication Rate22. Choose 9600 bps from the menu, shown below lef

Page 53 - Progress

Updating the Firmware - Xmodem (Serial) MethodA13Notes

Page 54

Updating the Firmware - Xmodem (Serial) MethodA14

Page 56

Introduction21.0 INTRODUCTIONThe Liebert® IntelliSlot® Web Card family delivers enhanced communications and control to Liebert AC Power and Precision

Page 57

Ensuring The High AvailabilityOf Mission-Critical Data And Applications.Emerson Network Power, the global leader in enabling business-criticalcontinui

Page 58

Introduction31.2 Web SupportThe Liebert IntelliSlot Web card delivers Web management and control to Liebert equipment. All authorized users on your ne

Page 59

Installation42.0 INSTALLATION2.1 Install a Liebert IntelliSlot Web Card—Non-Adapter VersionFollow these steps to install a Liebert IntelliSlot Web car

Page 60 - SL-52615_REV02_08-08

Installation52.2 Install a Liebert IntelliSlot Web/485 Card With AdapterFollow these steps to install a Liebert IntelliSlot Web/485 Card With Adapter