Page 1 - UPStation GXT 2U™

POWER PROTECTIONUPStation GXT 2U™USER MANUAL700-3000VA120V

Page 2

6BATTERY CHARGERThe battery charger utilizes energy from the utility power and precisely regulates it to continuously “float charge” the batteries. Th

Page 3 - TABLE OF CONTENTS

7GXT 2U (REAR VIEW)Input Fuse/Circuit BreakerAC InputSupport BaseOutput ReceptaclesExternal Battery ConnectorCooling FanIntellislot PortDB-9 Communica

Page 4

8 INSTALLATIONPREPARATION1. Visually inspect the UPS for freight damage. Report damage to the carrier and your local dealer or Liebert representativ

Page 5 - SAVE THESE INSTRUCTIONS

9RACK-MOUNT UPS CONVERSION AND INSTALLATION1. For slide rail installations, first remove the top/side fin. Slide thetop/side fin forward, then lift it

Page 6

103. Fasten the inner members from Step 2 to the UPS on both sides (see below) with eight screws provided in the accessories box of the UPS.4. Attach

Page 7 - GLOSSARY OF SYMBOLS

117. Insert the UPS, with inner members attached from Step 3, into the slide assemblies. You may need to depress the locking mechanisms on the inner a

Page 8 - INTRODUCTION

12EXTERNAL BATTERY CABINET INSTALLATIONOptional Liebert external battery cabinets may be connected to the UPS to provide additional battery run time.

Page 9 - MAJOR COMPONENTS

13 CONTROLS AND INDICATORSON/Alarm Silence/Manual Battery Test ButtonThis button controls output power to connected load(s) and has three functions:

Page 10 - DYNAMIC BYPASS

14Standby/Manual Bypass ButtonThis button controls output power to connected load(s) and hasdual functions: Standby and Manual Bypass.Load/Battery Lev

Page 11 - GXT 2U (REAR VIEW)

15Output Voltage Selection The Output Voltage is user configurable, and is designed to allow select-ing or changing the desired output voltage to matc

Page 13

16 OPERATING INSTRUCTIONSNORMAL MODE OPERATIONDuring normal operation, utility power provides energy to the UPS. The filters, power factor correctio

Page 14

17 COMMUNICATIONSCOMMUNICATIONS INTERFACE PORTThe UPStation GXT 2U UPS contains a standard DB-9 serial port female connector located on the rear of

Page 15 - UPStation GXT

183. A battery shutdown signal on Pin 4 will NOT cause an immediate shutdown. A shutdown signal will start a 2-minute shutdown timer. The timer cannot

Page 16

19 CONFIGURATION PROGRAMThis is a new feature included with the new UPStation GXT 2U line. Sev-eral UPS settings that were previously not available

Page 17 - CONTROLS AND INDICATORS

20 MAINTENANCEThe UPStation GXT 2U requires very little maintenance. The batteries are valve regulated, nonspillable, flame retardant, lead acid, an

Page 18

21Internal Battery Replacement Procedures:1. Gently remove the front plastic bezel cover from the UPS.2. Loosen and remove the four screws on the fron

Page 19

22FUSE REPLACEMENT1. Remove the input fuse from the fuse holder on the rear of the unit.2. Locate the spare input fuse that is shipped with the UPS.3.

Page 20 - OPERATING INSTRUCTIONS

23 TROUBLESHOOTINGThe information below indicates various symptoms a user may encounter in the event the UPStation GXT 2U™ develops a problem. Use t

Page 21 - COMMUNICATIONS

24Under fault conditions, the fault indicators will be illuminated indefinitely while battery charger is operational, or for a maximum of 5 minutes wh

Page 22 - NTELLIGENT COMMUNICATIONS

25Fault and Bypass indicator LEDs and diagnostic LED A are illuminated.UPS internal fan has a problem or UPS shutdown due to temperature condition. Lo

Page 23 - CONFIGURATION PROGRAM

i TABLE OF CONTENTSIMPORTANT SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . 1GLOSSARY OF SYMBOLS . . . . . . . . . . . . . . . . . .

Page 24 - MAINTENANCE

26AC LED is flashing. UPS detected a line-to-neutral reversal or a loss of proper grounding; continuous horn and UPS will not start.This is active onl

Page 25

27Alarm ConditionsCondition AlarmBattery Mode(utility failure)One short beep every 10 seconds; more than 2 minutes of run time remainingLow Battery Tw

Page 26 - FUSE REPLACEMENT

28 SPECIFICATIONSModel Number GXT2-700RT120 GXT2-1000RT120 GXT2-1500RT120Model Rating 700VA / 490W 1000VA / 700W 1500VA / 1050WDIMENSIONS in (mm)Uni

Page 27 - TROUBLESHOOTING

29SPECIFICATIONS (CONTINUED)Model Number GXT2-2000RT120 GXT2-3000RT120Model Rating 2000VA / 1400W 3000VA / 2100WDIMENSIONS in (mm)UnitW x D x H in. (m

Page 28 - Troubleshooting Guide

30 BATTERY CABINET SPECIFICATIONSModel Number GXT2-48VBATT GXT2-72VBATTUsed w/ UPS ModelGXT2-700RT120GXT2-1000RT120GXT2-1500RT120GXT2-2000RT120GXT2-

Page 29 - Problem Cause Solution

31 BATTERY RUN TIMESLoad% 700VA 1000VA 1500VA 2000VA 3000VAInternal Battery(minutes)10% 248 191 144 56 9120%1158753334630% 79 48 38 26 3040% 58 34 2

Page 32 - SPECIFICATIONS

Technical SupportUnited States1050 Dearborn DriveP.O. Box 29186Columbus, OH 43229Single-Phase UPS800-222-5877Outside the United States614-841-67553-Ph

Page 33 - SPECIFICATIONS (CONTINUED)

iiCOMMUNICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Communications Interface Port . . . . . . . . . . . . . . . . . .

Page 34

1 IMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONSThis manual contains important safety instructions. Read all safety, instal-lation, and operat

Page 35 - BATTERY RUN TIMES

2This UPS contains no user serviceable parts except the internal battery packs and the rear input line fuses. The UPS ON/Standby push buttons do not e

Page 36

3 GLOSSARY OF SYMBOLS•Risk of electrical shockIndicates caution followed by important instructionsAC inputAC outputRequests the user to consult the

Page 37

4 INTRODUCTIONCongratulations on your choice of the Liebert UPStation GXT 2U™ Unin-terruptible Power System (UPS). It provides conditioned power to

Page 38 - UPStation GXT 2U

5 MAJOR COMPONENTSTRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) AND EMI/RFI FILTERSThese UPS components provide surge protection and filter both electr