Emerson Fisher YD & YS Manuel d'instructions Page 1

Naviguer en ligne ou télécharger Manuel d'instructions pour Autres dispositifs de saisie Emerson Fisher YD & YS. Emerson Fisher YD & YS Instruction Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 32
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
www.Fisher.com
Fisherr YD and YS 3-Way Valves
Contents
Introduction 1.................................
Scope of Manual 1.............................
Specifications 2...............................
Educational Services 2...........................
Installation 3..................................
Maintenance 4.................................
Packing Lubrication 5..........................
Packing Maintenance 6.........................
Packing Replacement 6.....................
Trim Maintenance 7...........................
Disassembly 7.............................
Assembly 12..............................
ENVIRO-SEALt Bellows Seal Bonnet 16...........
Replacing a Plain or Extension Bonnet with an
ENVIRO-SEAL Bellows Seal Bonnet
(Stem/Bellows Assembly) 16..............
Replacement of an Installed
ENVIRO-SEAL Bellows Seal Bonnet
(Stem/Bellows Assembly) 18..............
Purging the ENVIRO-SEAL
Bellows Seal Bonnet 19...................
Parts Ordering 24...............................
Parts Kits 24...................................
Gasket Kits 25.................................
Parts List 26...................................
YD and YS Valve 26............................
Bonnet for YD and YS 26........................
Figure 1. Fisher YD Valve with 667 Actuator
W2081
Introduction
Scope of Manual
This instruction manual includes installation, maintenance, and parts information for NPS 1/2 through 8 YD and NPS
1/2 through 6 YS control valves. Refer to separate manuals for instructions covering the actuators and accessories.
Do not install, operate, or maintain YD or YS valves without being fully trained and qualified in valve, actuator, and
accessory installation, operation, and maintenance. To avoid personal injury or property damage, it is important to
carefully read, understand, and follow all the contents of this manual, including all safety cautions and warnings. If you
have any questions about these instructions, contact your Emerson Process Management sales office before
proceeding.
Instruction Manual
D100425X012
YD and YS Valves
October 2014
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - Introduction

www.Fisher.comFisherr YD and YS 3-Way ValvesContentsIntroduction 1...Scope of Manual 1...Speci

Page 2 - Educational Services

Instruction ManualD100425X012YD and YS ValvesOctober 201410Figure 6. PTFE Packing Arrangements for Use in Fisher ENVIRO-SEAL Bellows Seal BonnetsUPPER

Page 3 - Installation

Instruction ManualD100425X012YD and YS ValvesOctober 201411Figure 7. Double Graphite Ribbon/Filament Arrangements for Use in Fisher ENVIRO-SEAL Bellow

Page 4 - Maintenance

Instruction ManualD100425X012YD and YS ValvesOctober 201412CAUTIONNever use an old stem with a new valve plug. The use of an old stem requires drillin

Page 5 - Packing Lubrication

Instruction ManualD100425X012YD and YS ValvesOctober 201413CAUTIONNever use an old stem with a new valve plug. The use of an old stem requires drillin

Page 6 - Packing Maintenance

Instruction ManualD100425X012YD and YS ValvesOctober 20141412. Lubricate the valve stud bolts or cap screws (key 15) and install the nuts (key 16) on

Page 7 - Trim Maintenance

Instruction ManualD100425X012YD and YS ValvesOctober 20141513. Mount the bonnet onto the valve with the lubricator or pipe plug parallel with the pipe

Page 8

Instruction ManualD100425X012YD and YS ValvesOctober 201416Locate the pilot hole in the valve plug and drill the hole through the plug and stem assemb

Page 9

Instruction ManualD100425X012YD and YS ValvesOctober 201417CAUTIONTo prevent possible product damage, c over the opening in the valve in the following

Page 10 - Instruction Manual

Instruction ManualD100425X012YD and YS ValvesOctober 20141811. Place a new gasket (key 22) over the stem/bellows assembly. Place the new ENVIRO-SEAL b

Page 11

Instruction ManualD100425X012YD and YS ValvesOctober 201419can be installed. If the existing valve plug is reused, and the adaptor is in good conditio

Page 12 - Assembly

Instruction ManualD100425X012YD and YS ValvesOctober 20142Table 1. SpecificationsValve Sizes, Ratings, and End Connections(1,2)Cast Iron ValvesFlanged

Page 13

Instruction ManualD100425X012YD and YS ValvesOctober 2014201. Remove the two diametrically opposed pipe plugs (key 16).2. Connect a purging fluid to o

Page 14 - YD (High Temperature)

Instruction ManualD100425X012YD and YS ValvesOctober 201421Figure 10. Fisher YD Valve (Standard)40A3552-FCOMMON PORTFigure 11. Fisher YD Valve (High T

Page 15

Instruction ManualD100425X012YD and YS ValvesOctober 201422Figure 12. Fisher NPS 8 YD Valve54B9114-AVIEW DCOMMON PORT

Page 16 - (Stem/Bellows Assembly)

Instruction ManualD100425X012YD and YS ValvesOctober 201423Figure 13. Fisher Standard BonnetAU3910-AE1087PLAIN BONNETFigure 14. Fisher Extension Bonne

Page 17

Instruction ManualD100425X012YD and YS ValvesOctober 201424Parts OrderingEachvalveisassignedaserialnumberwhichcanbefoundonthevalve.Thissamenumberalsoa

Page 18

Instruction ManualD100425X012YD and YS ValvesOctober 201425Gasket KitsGasket KitsVALVE SIZE, NPSYD(Includes keys 9, 11, 14, and 22)YS(Includes keys 9,

Page 19

Instruction ManualD100425X012YD and YS ValvesOctober 201426Figure 16. Typical Fisher HIGH-SEAL Graphite ULFPacking System39B4153-A1. FIND NUMBER 219 N

Page 20

Instruction ManualD100425X012YD and YS ValvesOctober 201427Keys 2*, 5*, and 6* Valve Plug and Stem Assembly for Plain BonnetVALVE SIZE, NPSSTEM DIAMET

Page 21

Instruction ManualD100425X012YD and YS ValvesOctober 201428Key 5* Valve Plug StemVALVE SIZE,NPSSTEM SIZE VALVE STEM CONNECTION YD, S31600 (316 SST) YS

Page 22

Instruction ManualD100425X012YD and YS ValvesOctober 201429Key 9* Bonnet Gasket and Key 22* ShimVALVE SIZE,NPSKEY 9 (YD & YS) KEY 22 (YD & YS)

Page 23

Instruction ManualD100425X012YD and YS ValvesOctober 20143InstallationWARNINGAlways wear protective gloves, clothing, and eyewear when performing any

Page 24 - Parts Kits

Instruction ManualD100425X012YD and YS ValvesOctober 201430Keys 3, 4, 9, 11, 14, and 19 (NPS 8 YD Only)PLUG/ CAGE / STEMKEY 3CAGE RETAINERKEY 4GASKET,

Page 25 - Gasket Kits

Instruction ManualD100425X012YD and YS ValvesOctober 201431Key Description Part NumberFilamentpackingringforNPS3and4with 12.7 mm (1/2 inch) stem (4 re

Page 26 - Parts List

Instruction ManualD100425X012YD and YS ValvesOctober 201432Emerson Process ManagementMarshalltown, Iowa 50158 USASorocaba, 18087 BrazilChatham, Kent M

Page 27

Instruction ManualD100425X012YD and YS ValvesOctober 20144heat treating is to be performed, all trim parts should be removed. Contact your Emerson Pro

Page 28

Instruction ManualD100425X012YD and YS ValvesOctober 20145D Use bypass valves or completely shut off the process to isolate the valve from process pre

Page 29

Instruction ManualD100425X012YD and YS ValvesOctober 20146Packing MaintenanceNoteFor valves with ENVIRO-SEAL packing, see the Fisher instruction manua

Page 30

Instruction ManualD100425X012YD and YS ValvesOctober 201471. Remove the actuator and bonnet according to steps 1 through 4 of the Disassembly procedur

Page 31

Instruction ManualD100425X012YD and YS ValvesOctober 20148WARNINGSee the WARNING at the beginning of the Maintenance section for more information.2. D

Page 32

Instruction ManualD100425X012YD and YS ValvesOctober 20149Figure 4. Detail of Fisher PTFE/Composition Packing ArrangementsUPPER WIPER(KEY 12)PACKINGFO

Commentaires sur ces manuels

Pas de commentaire