Precision Cooling
For Business-Critical Continuity™
Liebert
®
Xtreme Density
System Design Manual
Vue de la page 0
1 2 3 4 5 6 ... 83 84

Résumé du contenu

Page 1 - Xtreme Density

Precision CoolingFor Business-Critical Continuity™Liebert® Xtreme Density™System Design Manual

Page 2 -

System Description41.3 Liebert XDV—Vertical, Above-Cabinet Cooling ModuleThe Liebert XDV is installed on top of or above a rack enclosure. It is avail

Page 3 - TABLE OF CONTENTS

System Description51.4 Liebert XDH—Horizontal Cooling ModuleThe Liebert XDH cooling module is designed to be placed within a row of server enclosures

Page 4

System Description61.5 Liebert XDCFThe Liebert XDCF is a self-contained module designed to cool Egenera’s BladeFrame EX cabinets and equipment without

Page 5

System Description71.6 Liebert XDA—Air Flow EnhancerThe Liebert XDA is a fan unit that boosts the airflow through densely populated enclosures, removi

Page 6

System Description81.7 Liebert XDP—Pumping UnitThe Liebert XDP isolates the building’s chilled water circuit from the pumped refrigerant circuit. The

Page 7 - 1.0 SYSTEM DESCRIPTION

System Description91.8 Liebert XDC—Refrigerant ChillerThe Liebert XDC is an indoor chiller that connects directly to the Liebert XD cooling modules an

Page 8

System Description101.9 Liebert XD PipingLiebert XD Piping is prefabricated distribution piping that is installed in anticipation of a growing sys-tem

Page 9

System Description11Figure 13 Liebert XD connection port kitTable 1 Liebert XD field-installed port kits header connection sizeAssembly P# Supply Head

Page 10

Starting a New Equipment Cooling Project122.0 STARTING A NEW EQUIPMENT COOLING PROJECT2.1 Determining Cooling Equipment Needs1. Is adequate space avai

Page 11 - System Description

Starting a New Equipment Cooling Project132.2 Implementing a Hot-Aisle/Cold Aisle DesignA best practice is to use rows of equipment racks in an altern

Page 13

Designing a Liebert XD Solution143.0 DESIGNING A LIEBERT XD SOLUTIONLiebert XD systems are intended for use with precision air conditioning equipment,

Page 14 - Liebert XDP Minimum Load

Designing a Liebert XD Solution153.3 Selecting Liebert XD Cooling ModulesThe next step is to select the Liebert XD cooling modules to be configured in

Page 15 - Liebert XDC Minimum Load

Designing a Liebert XD Solution16Different types of Liebert XD cooling modules may be connected to the same Liebert XDP or Liebert XDC as long as the

Page 16 - 1.9 Liebert XD Piping

Designing a Liebert XD Solution17Table 3 can be used to determine the correct number and spacing of Liebert XDOs.Table 3 Calculating quantity and spac

Page 17

Designing a Liebert XD Solution183.6.2 Determining Vertical Placement of Liebert XDOs Above the Cold AisleIn the maximum density configuration, Lieber

Page 18

Designing a Liebert XD Solution19Figure 17 Positioning Liebert XDV on top of cabinetBoth of the Liebert XDV’s power cords should be connected to power

Page 19

Designing a Liebert XD Solution203.8 Liebert XDCF PlacementThe Liebert XDCF is a self-contained module designed to cool Egenera’s BladeFrame EX cabine

Page 20

Designing a Liebert XD Solution213.9 Liebert XDH PlacementThe free-standing Liebert XDH cooling unit is best placed among the equipment cabinets in a

Page 21

Designing a Liebert XD Solution223.11 Examples of Expansion and Interlaced Connection of Liebert XD Cooling ModulesFigure 20 Liebert XDV units mounted

Page 22 - 3.6 Liebert XDO Placement

Designing a Liebert XD Solution23Figure 22 Liebert XDV units mounted on racks emitting 8kW of heat top viewFigure 23 Liebert XDV units mounted on rack

Page 23

iTABLE OF CONTENTS1.0 SYSTEM DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.1

Page 24

Designing a Liebert XD Solution243.12 Liebert XD RefrigerantThe refrigerant used in the Liebert XD system is HFC-134a (1,1,1,2-tetrafluoroethane), mad

Page 25

Designing a Liebert XD Solution253.13 Liebert XD Piping System DesignAll piping must be ASTM (American Society for Testing and Materials) Type “L” cop

Page 26 - 3.8 Liebert XDCF Placement

Designing a Liebert XD Solution26Figure 25 Hydraulic diagram3.14 Liebert XD Piping SlopeThe main supply and return lines to and from the XDP/XDC must

Page 27 - 3.9 Liebert XDH Placement

Designing a Liebert XD Solution27Figure 26 Bypass flow controller details, dimensionsFigure 27 Bypass flow controller arrangement Figure 28 Bypass flo

Page 28 - Interlaced piping arrangement

Designing a Liebert XD Solution283.16 Determining Refrigerant VolumeAfter the preliminary system design is completed, Tables 7, through 15 may be used

Page 29

Designing a Liebert XD Solution29Table 10 R-134a refrigerant charge for Flex Pipe connector lines to and from any modelLiebert XDO/Liebert XDH/Liebert

Page 30 - 3.12 Liebert XD Refrigerant

Designing a Liebert XD Solution303.16.2 Calculating Refrigerant Charge—ExampleUsing Tables 7, 8, 9 and 10, calculate the refrigerant charge of the ind

Page 31 - Liebert XDC

Designing a Liebert XD Solution313.18 Chilled Water PipingThe Liebert XDP is offered only with a two-way chilled water control valve. Some application

Page 32 - 3.15 Bypass Flow Controllers

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF324.0 LIEBERT XD COOLING MODULES—LIEBERT XDO, LIEBERT XDV, LIEBERT XD

Page 33 - Liebert XDP

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF33Figure 29 Dimensional data—Liebert XDO hard-piped units24-1/8"

Page 34

ii4.0 LIEBERT XD COOLING MODULES—LIEBERT XDO, LIEBERT XDV, LIEBERT XDHAND LIEBERT XDCF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 35

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF34Figure 30 Dimensional data—Liebert XDO with pre-charged optionRear

Page 36

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF35Figure 31 Liebert XDO internal mounting location DPN000771 Pg. 5 R

Page 37 - 3.19 Electrical

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF36Figure 32 Liebert XDO top and front electrical access points4.2 Lie

Page 38 - LIEBERT XDCF

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF374.2.1 Optional Features—Liebert XDV• Refrigerant Pre-Charge—Liebert

Page 39

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF38Figure 34 Liebert XDV dimensions with one-shot connectionDetailArea

Page 40 - Right Side of XDO

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF39Figure 35 Liebert XDV electrical connections for CE approved unitsP

Page 41

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF40Figure 36 Liebert XDV electrical connections for CSA-approved units

Page 42

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF41Figure 37 Suspending single Liebert XDV from UnistrutsFigure 38 Sus

Page 43 - Return (Out)

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF42Figure 39 Alternative mounting methods—mounting multiple Liebert XD

Page 44 - Detail “A”

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF434.3 Liebert XDCF Standard FeaturesThe Liebert XDCF is a self-contai

Page 45 - SECONDARY

iiiFigure 25 Hydraulic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 46

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF444.4 Liebert XDCF Mechanical ConsiderationsThe Liebert XDCF is engin

Page 47

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF454.5 Liebert XDCF Installation ConsiderationsNo cutting or drilling

Page 48

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF464.6.1 Header SystemThe Liebert XDCF module system requires use of t

Page 49 - XDH, XDO or XDV

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF47Figure 44 Liebert XDH dimensionsFigure 45 Supply and return piping

Page 50 - Figure 41 Overall dimensions

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF484.7.2 Piping Connections to Liebert XDP or Liebert XDCPiping Instal

Page 51

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF494.8 Liebert XD Flex Pipe KitFlex Pipe kits are available in lengths

Page 52 - 4.6.1 Header System

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF504.9 Liebert XD Piping Dimensions and Features4.9.1 Piping Installat

Page 53 - Detail "A"

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF51Figure 49 Four-port prefabricated piping for Liebert XD cooling mod

Page 54 - Refer to Table 5 for details

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF52Figure 50 Five-port prefabricated piping for Liebert XD cooling mod

Page 55 - 4.8 Liebert XD Flex Pipe Kit

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF53Figure 51 Ten-port prefabricated piping for Liebert XD cooling modu

Page 56 - Page 1, Rev. 3

ivTABLESTable 1 Liebert XD field-installed port kits header connection size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Table 2 Max

Page 57 - Page 2, Rev. 3

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF544.10 Liebert XDP Standard Features• Heat Exchanger—Brazed plate des

Page 58 - Page 3, Rev. 3

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF55Figure 53 Liebert XDP piping access points and external featuresTab

Page 59 - Page 4, Rev. 3

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF56Figure 54 Front view of Liebert XDP and electrical enclosure Figure

Page 60 - Floor Cutout Dimensions

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF57Figure 56 Liebert XDP 60Hz high voltage connectionsFigure 57 Lieber

Page 61 - 16-1/8"

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF584.11 Liebert XDC Standard Features• Compressors—Scroll with a sucti

Page 62 - Front of Liebert XDP

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF59Figure 59 Liebert XDC piping locationsTable 25 Liebert XD Chiller p

Page 63

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF60Figure 60 Positioning a water/glycolLiebert XDC for placement on a

Page 64 - Page 2, Rev. 6

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF61Figure 61 Piping locations—floor stand and valve assemblyShaded are

Page 65 - 50/60Hz A B C D E F G

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF62Figure 62 Front view of Liebert XDC and electrical enclosuresFigure

Page 66 - * Threaded Female Conection

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF63Figure 64 Liebert XDC high voltage connections—primary disconnect s

Page 67

System Description11.0 SYSTEM DESCRIPTIONThe Liebert XD™ family of cooling units delivers efficient, sensible cooling to high-heat environ-ments. Lieb

Page 68 - Not Shown for Clarity

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF64Figure 66 Liebert XDC high voltage connections—secondary disconnect

Page 69

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF65Figure 68 Liebert XDC heat rejection electrical connection pointsFi

Page 70

Liebert XD Cooling Modules—Liebert XDO, Liebert XDV, Liebert XDH and Liebert XDCF66Figure 70 Liebert XDC Extra Low Voltage field connections pointsCon

Page 71 - Electrical handy box

Specifications675.0 SPECIFICATIONSTable 27 Liebert XDC160 specificationsModelsXDC160 AirXDC160 Water / GlycolXDC160AA XDC160AM189192G3189192G5Cooling

Page 72

Specifications68Table 28 Floor stand specifications—water-cooled Liebert XDCModels - 60 Hz XDC160 Water Floor Stand - 60HzEntering Fluid Temp °F (C) 6

Page 73 - 5.0 SPECIFICATIONS

Specifications69Table 30 Floor stand specifications—Liebert XDC with 40% ethylene glycolModels - 60 Hz XDC160 Glycol Floor Stand - 60Hz - 40% EGOutsid

Page 74

Specifications70Table 31 Liebert XDP160 specificationsModels XDP160RC XDP160RA XDP160RMCooling Capacity, Nominal160 kW / 46 Tons, 60Hz 140 kW / 40 Ton

Page 75 - Piping Connections

Specifications71Table 32 Liebert XDO16 specificationsModelsXDO16BK--0XDO16DK--0XDO16BK-E0XDO16DK-E0XDO16BKP-0XDO16BKPE0XDO16DKP-0XDO16DKPE0(60Hz)XDO16

Page 76

Specifications72Table 33 Liebert XDO20 specificationsModelsXDO20DK--*; XDO20BKP-*XDO20DKP-*; XDO20BK-E*XDO20DK-E*; XDO20BKPE*XDO20DKPE*XDO20BS--*; XDO

Page 77

Specifications73Table 34 Liebert XDO20 dimensions—domestic and exportModelShipping Dimensions, inches (mm)Unit DimensionUnpacked, inches (mm)Domestic

Page 78 - * = Revision level

System Description21.1 Direct and Indirect System ConfigurationsLiebert XD systems are available in Direct and Indirect configurations—differentiated

Page 79 - * Includes piping connections

Specifications74Table 36 Liebert XDV8 specificationsModelsXDV8BK--*; XDV8DK--*XDV8BKP-*; XDV8DKP-*XDV8BK-E*; XDV8DK-E*XDV8BKPE*; XDV8DKPE*XDV8BKR-*; X

Page 80 - * = Revision level of unit

Specifications75Table 37 Liebert XDV10 specificationsModelsXDV10BK--*; XDV10DK--*XDV10BKP-*; XDV10DKP-*XDV10BK-E*; XDV10DK-E*XDV10BKPE*; XDV10DKPE*XDV

Page 81

Specifications76Table 38 Liebert XDV8 dimensions—domestic and exportModelShipping DimensionsLength x Width x Heightinches (mm)Unit Dimensions Unpacked

Page 82

Specifications77Table 41 Liebert XDH specificationsModelsXDH20DKP-0XDH20DK--0XDH20BKP-0XDH20BK--0XDH20DKPE0XDH20DK-E0XDH20BKPE0XDH20BK-E0(60Hz)XDH32DK

Page 83 - Number of Fans

Ensuring The High Availability0f Mission-Critical Data And Applications.Emerson Network Power, the global leader in enabling business-criticalcontinui

Page 84

System Description31.2 Liebert XDO—Overhead Cooling ModuleThe Liebert XDO ceiling-mounted cooling module draws in hot air rising from densely populate

Commentaires sur ces manuels

Pas de commentaire