Emerson ROSEMOUNT 5300 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Mesure, test et contrôle Emerson ROSEMOUNT 5300. Product Data Sheet Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 42
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Product Data Sheet
00813-0100-4530, Rev AA
Catalog 2008 - 2009
Rosemount 5300 Series
www.rosemount.com
The Rosemount 5300 Series is our premium 2-wire
guided wave radar for challenging level and interface
measurements on liquids, slurries and solids.
It delivers everything you would expect from a
best-in-class process radar – superior reliability,
state-of-the-art safety features, effortless handling,
and unlimited connectivity.
Long measuring ranges and reliable
measurements on low-reflective media due to
Direct Switch Technology and Probe End
Projection function.
± 3 mm accuracy with advanced timing method.
Application flexibility with full range of probe styles.
Less instruments and process penetration with a
Multivariable™ transmitter.
Powerful and easy-to-use configuration tools.
Reduced cost and increased safety thanks to a
robust modular design.
Increased plant availability with Advanced
PlantWeb
®
functionality.
Improved EMC performance with a smart galvanic
interface.
Virtually unaffected by application conditions.
Content
Taking Guided Wave Radar Benefits to the Next Level . . . . . . . . . . . . . . . . . . . . . . Level-2
Optimized to Suit More Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-3
System Integration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-4
Select Guided Wave Radar Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-6
Measuring Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-11
Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-12
Replacing a Displacer in an Existing Displacer Cage. . . . . . . . . . . . . . . . . . . . . . . Level-13
Solids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-14
Mechanical Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-15
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-17
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-21
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-23
Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-32
High Performance Guided Wave Radar
Vue de la page 0
1 2 3 4 5 6 ... 41 42

Résumé du contenu

Page 1 - Rosemount 5300 Series

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 Serieswww.rosemount.comThe Rosemount 5300 Series is our premium 2-wire guid

Page 2

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-10In the table below: G=Good, NR=Not Recommended, AD=Applicatio

Page 3

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-11Rosemount 5300 SeriesMeasuring RangeIn the table below, measuring range informatio

Page 4 - System Integration

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-12InterfaceRosemount 5302 is the ideal choice for measuring the

Page 5

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-13Rosemount 5300 SeriesReplacing a Displacer in an Existing Displacer CageA Rosemoun

Page 6 - Transmitter

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-14SolidsRosemount 5303 is the perfect choice for most solid app

Page 7

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-15Rosemount 5300 SeriesMechanical ConsiderationsTypically the transmitter is top mou

Page 8

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-16• For optimal single lead probe performance in non-metallic v

Page 9

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-17Rosemount 5300 SeriesSpecificationsGeneralProduct Rosemount 5300 Series Guided Wav

Page 10

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-18ElectricPower Supply HART®: 16-42.4 V dc (16-30 V dc in IS ap

Page 11 - Measuring Range

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-19Rosemount 5300 SeriesEnvironmentAmbient Temperature Non-Hazardous, HART® communica

Page 12 - Interface

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-2Taking Guided Wave Radar Benefits to the Next LevelMEASUREMENT

Page 13

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-20POWER SUPPLY4-20 mA with HART® The input voltage (UI)for HART

Page 14

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-21Rosemount 5300 SeriesProduct CertificationsSAFETY NOTEA safety isolator such as a

Page 15 - Mechanical Considerations

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-22Canadian Standards Association (CSA) ApprovalCert. no. 151465

Page 16

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-23Rosemount 5300 SeriesDimensional DrawingsCOAXIAL PROBE WITH FLANGE CONNECTIONL ≤ 2

Page 17 - Specifications

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-24COAXIAL PROBE WITH THREADED CONNECTIONL ≤ 20 feet (6 m)NPT 1/

Page 18

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-25Rosemount 5300 SeriesRIGID TWIN LEAD PROBE1.0 (26)s605.2 (133)7.4 (187)1.8 (45)7.1

Page 19

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-26FLEXIBLE TWIN LEAD PROBE1.4 (35)s603.5 (90)3.5 (90)Ø 0.16 (4)

Page 20

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-27Rosemount 5300 SeriesRIGID SINGLE LEAD PROBE WITH FLANGE CONNECTIONL ≤ 10 feet (3

Page 21 - Product Certifications

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-28RIGID SINGLE LEAD PROBE WITH THREADED CONNECTIONNPT 1/1½ inch

Page 22

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-29Rosemount 5300 SeriesFLEXIBLE SINGLE LEAD PROBE WITH FLANGE CONNECTION5.2 (133)7.1

Page 23 - Dimensional Drawings

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-3Rosemount 5300 SeriesOptimized to Suit More ApplicationsThe Rosemount 5300 offers r

Page 24

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-30FLEXIBLE SINGLE LEAD PROBE WITH THREADED CONNECTION5.5 (140):

Page 25

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-31Rosemount 5300 SeriesSPECIAL FLANGES AND FLUSHING CONNECTION RINGSMasoneilan and F

Page 26

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-32Ordering InformationMODEL CODE 5301 AND 5302 LEVEL AND/OR INT

Page 27

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-33Rosemount 5300 SeriesCode Total Probe Length (9) (feet/m)xxx 0-164 ft or 0-50 mCod

Page 28

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-34Code Process Connection - Size / Type (consult factory for ot

Page 29

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-35Rosemount 5300 SeriesCode Hazardous Locations CertificationsKH FM, CSA, IECEx Intr

Page 30

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-36MODEL CODE 5303, LEVEL FOR SOLIDS Model Product Description53

Page 31

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-37Rosemount 5300 SeriesCode Process Connection - Size / Type (consult factory for ot

Page 32 - Ordering Information

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-38Code Hazardous Locations CertificationsNA No Hazardous Locati

Page 33

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-39Rosemount 5300 SeriesACCESSORIESCode Process Connection - Size/Type (consult facto

Page 34

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-4System IntegrationINPUTS / OUTPUTSThe 5300 Series transmitter

Page 35

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-40

Page 36

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-41Rosemount 5300 Series

Page 37

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 Series© 2008 Rosemount Inc. All rights reserved.Standard Terms and Conditio

Page 38

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-5Rosemount 5300 SeriesThe transmitter is available with Intrinsically Safe(1) / Non-

Page 39

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-6For 4-20 mA or HART®, a HART® modem is required for communicat

Page 40

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-7Rosemount 5300 SeriesTANK CONNECTIONThe tank connection consists of a tank seal, a

Page 41

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Rosemount 5300 SeriesLevel-8Flange Rating•ANSI:According to ANSI B16.5 Table 2-2.3.Standar

Page 42

Product Data Sheet00813-0100-4530, Rev AACatalog 2008 - 2009Level-9Rosemount 5300 SeriesTransition ZonesTransition zones are areas where measurements

Commentaires sur ces manuels

Pas de commentaire