Emerson CF775AW02 Manuel du propriétaire Page 8

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 12
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 7
5. Secure the ceiling cover in place by sliding lock-
washers over the threaded studs and installing the
two knurled knobs (supplied). (Figure 16.) Tighten
the knurled knobs securely until the ceiling cover
fits snugly against the ceiling and the hole in the
ceiling cover is clear of the downrod. Your fan is
now wired to be turned on and off from the fan
switch.
6. Connect the wood ball with chain to the 3-speed
switch pull chain.
8
How to Wire Your Ceiling Fan
If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
1. Connect the green grounding lead from the hanger
ball and the green grounding lead from the hanger
bracket to the grounding conductor of supply (this
may be a bare wire or wire with green colored
insulation). Securely connect wires with wire con-
nectors supplied. (Figure 15.)
2. Securely connect the fan motor white wire to the
supply white (neutral) wire using wire connector
supplied (Figure 15). Securely connect the fan
motor black wire and blue wire to the supply black
(hot) wire using wire connector supplied
(Figure 15). After connections have been made,
turn leads upward and carefully push leads into the
outlet box, with the white and green leads on one
side of the outlet box and the black and blue leads
on the other side of the outlet box.
NOTE: CEILING COVER
OMITTED FOR CLARITY.
GROUND
WIRE
LISTED
WIRE
CONNECTOR (3)
GREEN WIRE
(GROUND) FROM
HANGER BRACKET
GREEN WIRE
(GROUND) FROM
HANGER BALL
WHITE SUPPLY
(NEUTRAL)
WHITE FAN
WIRE
BLACK SUPPLY
(HOT)
BLACK AND BLUE
FAN WIRES
Figure 4
Figure 15
3. Screw the two threaded studs (supplied) into the
tapped holes in the hanger bracket.
4. Lift the ceiling cover up to the threaded studs and
turn until studs protrude through the holes in the
ceiling cover (Figure 16).
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.
WARNING
To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is ground-
ed, contact a licensed electrician for advice, as it
must be grounded for safe operation.
WARNING
This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or acces-
sories not designated for use with this product by
Emerson Electric Co. could result in personal injury
or property damage.
WARNING
CEILING COVER
THREADED STUD
KNURLED KNOB
LOCKWASHERS (2)
Figure 16
To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box and
not pinched between the ceiling cover and the ceiling.
WARNING
U.L. Model No.: CF775
Vue de la page 7