Introducing the Liebert
®
DSE from
Emerson Network Power
In today’s data center, minimizing annual energy usage
while maintaining reliability is increasingly important. While
chilled-water loops operating at elevated temperatures
supported by water-side economizers have helped to
decrease energy usage, new innovations are changing how
the data center industry thinks about direct expansion (DX)
cooling infrastructures with respect to efciency, scalability
and reliability.
One such next generation DX system, the Liebert DSE
from Emerson Network Power, provides the following
key benets:
Industry-leading energy efciency among
DX systems
Hassle-free economization with Liebert EconoPhase™
Precise control and enhanced efciency through
intelligent controls
Uncompromising reliability and 24/7 support
This product brief will provide a thorough overview of
the Liebert DSE system and compare its unique design to
comparable DX and chilled-water cooling solutions you
may be considering for your data center. It also provides a
detailed explanation of the Liebert EconoPhase pumped
refrigerant economizer solution and share specic examples
for how cooling efciency can be maximized intelligently in
accordance with your data center’s ambient climate.
The Liebert DSE direct expansion cooling system comprises
four primary components: the Liebert DSE indoor computer
room air conditioning (CRAC) unit, the Liebert MC™
micro-channel outdoor condenser, the Liebert EconoPhase
pumped refrigerant economizer, and Liebert iCOM™
thermal system controls. The components operate in
harmony to provide the industry’s most energy efcient
operation for a room-based cooling system.
It is important to note that the Liebert DSE is a
complete, integrated system— not a collection
of disparate components.
The Liebert DSE direct expansion cooling system comprises four primary components: the Liebert DSE indoor computer room air
conditioning (CRAC) unit, the Liebert MC micro-channel outdoor condenser, the Liebert EconoPhase pumped refrigerant economizer
and Liebert iCOM control with thermal system manager.
Liebert MC: Intelligent, high
efficiency condensers
Liebert EconoPhase: First ever
pumped refrigerant economizer
Liebert iCOM
Thermal System Controls
Liebert DSE Indoor Unit: Next
generation data center cooling system