Emerson SR5 Fiche technique

Naviguer en ligne ou télécharger Fiche technique pour Non Emerson SR5. Emerson SR5 Data Sheet Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Bulletin 71.1:SR5
D103105X012
April 2008
www.emersonprocess.com/regulators
Optional T-Handle Available
Large Turndown Ratio
Self-Draining
Easy Maintenance Tight Shutoff
Superior Flow Performance and Accuracy
Highly Stable
Wide Control Range
Optional Diaphragm Support
Diaphragm Cycle Life
Covered Adjusting Screw
Sanitary Design Standards
Nonporous Polished Body and Internals
Remote Setpoint Capability
Figure 1.  Type SR5
Type SR5 Sanitary Pressure Regulator
Patents Pending
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - Bulletin 71.1:SR5

Bulletin 71.1:SR5D103105X012April 2008www.emersonprocess.com/regulators  Optional T-Handle Available  Large Turndown Ratio  Self-Draining  Easy Ma

Page 2

Bulletin 71.1:SR510Table 7. Cv Coefcients for 1-inch (DN 25) and 1-1/2 x 1-inch (DN 40 x 25) Bodies (continued)SPRING RANGE, PSIG (bar)SET PRESSURE

Page 3

Bulletin 71.1:SR511SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET PRESSURE, PSIG (bar)Cv AT % DROOP1-1/2-inch (DN 40) Full PortElastomer Diap

Page 4

Bulletin 71.1:SR512SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET PRESSURE, PSIG (bar)Cv AT % DROOP2-inch (DN 50)Elastomer Diaphragm Metal Di

Page 5

Bulletin 71.1:SR513Table 7. Cv Coefcients for 3-inch (DN 80) Body (continued)SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET PRESSURE, PSIG

Page 6

Bulletin 71.1:SR514SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET, PSIG (bar)CAPACITIES IN SCFH (Nm3/h) OF AIR AT % DROOP1/2-inch (DN 15) Bod

Page 7

Bulletin 71.1:SR515SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET, PSIG (bar)CAPACITIES IN SCFH (Nm3/h) OF AIR AT % DROOP3/4-inch (DN 20) Bod

Page 8

Bulletin 71.1:SR516SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET, PSIG (bar)CAPACITIES IN SCFH (Nm3/h) OF AIR AT % DROOP1-inch (DN 25) BodyE

Page 9

Bulletin 71.1:SR517SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET, PSIG (bar)CAPACITIES IN SCFH (Nm3/h) OF AIR AT % DROOP1-1/2 x 1-inch (DN 4

Page 10

Bulletin 71.1:SR518SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET PRESSURE, PSIG (bar)CAPACITIES IN SCFH (Nm3/h) OF AIR AT % DROOP1-1/2-inch

Page 11

Bulletin 71.1:SR519Table 8. Air Capacities for 2-inch (DN 50) Body (continued)SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET PRESSURE, PSIG

Page 12

Bulletin 71.1:SR52W8966Figure 2.  Type SR5Figure 3.  Type SR5 Operational SchematicINLET PRESSUREOUTLET PRESSUREATMOSPHERIC PRESSUREIntroductionThe Ty

Page 13

Bulletin 71.1:SR520SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET PRESSURE, PSIG (bar)CAPACITIES IN SCFH (Nm3/h) OF AIR AT % DROOP3-inch (DN

Page 14

Bulletin 71.1:SR521SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET, PSIG (bar)CAPACITIES IN POUNDS PER HOUR (kg/h) OF SATURATED STEAM AT % DRO

Page 15

Bulletin 71.1:SR522SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET, PSIG (bar)CAPACITIES IN POUNDS PER HOUR (kg/h) OF SATURATED STEAM AT % DRO

Page 16

Bulletin 71.1:SR523SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET, PSIG (bar)CAPACITIES IN POUNDS PER HOUR (kg/h) OF SATURATED STEAM AT % DRO

Page 17

Bulletin 71.1:SR524Table 9. Steam Capacities for 1-1/2 x 1-inch (DN 40 x 25) Body (continued)SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET,

Page 18

Bulletin 71.1:SR525SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET PRESSURE, PSIG (bar)CAPACITIES IN POUNDS PER HOUR (kg/h) OF SATURATED STEAM

Page 19

Bulletin 71.1:SR526Table 9. Steam Capacities for 2-inch (DN 50) Body (continued)SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET PRESSURE, PSI

Page 20

Bulletin 71.1:SR527Table 9. Steam Capacities for 3-inch (DN 80) Body (continued)SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET PRESSURE, PSI

Page 21

Bulletin 71.1:SR528SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET, PSIG (bar)CAPACITIES IN GPM (l/min) OF WATER AT % DROOP1/2-inch (DN 15) Bo

Page 22

Bulletin 71.1:SR529SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET, PSIG (bar)CAPACITIES IN GPM (l/min) OF WATER AT % DROOP3/4-inch (DN 20) Bo

Page 23

Bulletin 71.1:SR53Figure 4.  Type SR5 Performance ComparisonE0965Increasing Flow30 (2,1)25 (1,7)20 (1,4)15 (1,0)10 (0,7)5 (0,4)Outlet Pressure, psig (

Page 24

Bulletin 71.1:SR530SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET, PSIG (bar)CAPACITIES IN GPM (l/min) OF WATER AT % DROOP1-inch (DN 25) Body

Page 25

Bulletin 71.1:SR531SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET, PSIG (bar)CAPACITIES IN GPM (l/min) OF WATER AT % DROOP1-1/2 x 1-inch (DN

Page 26

Bulletin 71.1:SR532Table 10. Water Capacities for 2-inch (DN 50) Body (continued)SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET PRESSURE, PS

Page 27

Bulletin 71.1:SR533Table 10. Water Capacities for 3-inch (DN 80) Body (continued)SPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET PRESSURE, PS

Page 28

Bulletin 71.1:SR534D (MAX)GACJOptional T-HandleFigure 5.  DimensionsSIZE, INCHES (DN)DIMENSIONS, INCHES (mm)A C D G J1/2 (15) 3.00 (76) 5.11 (130) 7.

Page 29

Bulletin 71.1:SR535Product Ordering GuideBody Size (Select One) ¨ 1/2-inch (DN 15)**  ¨ 3/4-inch (DN 20)**  ¨ 1-inch (DN 25)** ¨ 1-1/2 x 1-inch (D

Page 30

Bulletin 71.1:SR5The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners

Page 31

Bulletin 71.1:SR54SpecicationsBody Size, Inlet and Outlet Connection 1/2 (DN 15), 3/4 (DN 20), 1 (DN 25), and 1-1/2-inch (DN 40) , 2 (DN 50), 3 (DN

Page 32

Bulletin 71.1:SR55Table 2.  Outlet Pressure Ranges and Control Spring DataBODY SIZE, INCHES (DN)OUTLET PRESSURE RANGES, PSIG (bar)COLORWIRE DIAMETER,

Page 33

Bulletin 71.1:SR56Table 5.  Materials of ConstructionPART MATERIALBody 316L Stainless Steel, 20 µin (0,5 µm) Ra with ElectropolishSpring Case 316 Stai

Page 34

Bulletin 71.1:SR57Capacity DataThe capacity information on the following pages is based on three offset factors, 10, 20 and 30 percent. Flow capacity

Page 35

Bulletin 71.1:SR58For Non-Critical Pressure DropsFor pressure drops lower than critical (absolute outlet pressure greater than one-half the absolute i

Page 36

Bulletin 71.1:SR59Table 7. Cv Coefcients for 1/2-inch (DN 15) and 3/4-inch (DN 20) BodiesSPRING RANGE, PSIG (bar)SET PRESSURE, PSIG (bar)INLET PRE

Commentaires sur ces manuels