Emerson ACE95Jr Fiche technique

Naviguer en ligne ou télécharger Fiche technique pour Non Emerson ACE95Jr. Emerson ACE95Jr Data Sheet Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 8
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Bulletin 74.1:ACE95JR
April 2012
D102722X012
www.sherregulators.com
Type ACE95jr Tank Blanketing Valve
Introduction
Tank blanketing is the process of using a gas, usually an
inert gas such as nitrogen, to maintain a slightly positive
pressure in an enclosed storage tank. Tank blanketing
prevents a stored product from vaporizing into the
atmosphere, reduces product combustibility, and prevents
oxidation or contamination of the product by reducing
its exposure to air. Tank blanketing is utilized with
various products, including: adhesives, pharmaceuticals,
pesticides, fertilizers, fuels, inks, photographic chemicals,
and food additives.
Type ACE95jr valves are self-contained, fully
balanced, and used for accurate pressure control on
tank blanketing systems. These valves help control
emissions and provide protection against atmospheric
contamination. Type ACE95jr valves maintain a positive
tank pressure which reduces the possibility of tank wall
collapse during pump out operations and prevents a
stored product from vaporizing to atmosphere.
Fully Balanced Plug
Design Reduces Inlet
Pressure Sensitivity
Stainless Steel
Construction Available
High Sensitivity
Self-Contained
Bubble
Tight
Shutoff
W8157
Figure 1. Type ACE95jr Tank Blanketing Valve
Vacuum
Settings
Available
Features
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - Bulletin 74.1:ACE95JR

Bulletin 74.1:ACE95JRApril 2012D102722X012www.sherregulators.comType ACE95jr Tank Blanketing ValveIntroductionTank blanketing is the process of using

Page 2

Bulletin 74.1:ACE95JR2SpecicationsSizes and End Connection Styles 1/2 NPT 1 x 1/2 NPT 1 NPT NPS 1/2 / DN 15, CL150 RF NPS 1

Page 3

Bulletin 74.1:ACE95JR 3When the actuator moves downward, it pushes open the valve plug which allows ow in to the tank. See Figure 2. When pressure

Page 4

Bulletin 74.1:ACE95JR4BLANKETING GASSUPPLY LINELINE STRAINERSHUTOFFVALVESENSINGLINESHUTOFFVALVESHUTOFFVALVETYPE 252INLET FILTEREMERGENCYTANK VENTBLANK

Page 5

Bulletin 74.1:ACE95JR 5Table 2. Flow Rate Conversion(1)MULTIPLY MAXIMUM PUMP RATE OUT:BY TO OBTAIN(1):U.S. GPMU.S. GPHm3/h8.0210.13371.01SCFHSCFHNm3/

Page 6

Bulletin 74.1:ACE95JR6Figure 4. Type ACE95jr DimensionsBODY SIZE,NPS / DNSTRUCTUREDIMENSIONSNPT CL150 RF Flange SanitaryANPS DN inches mm inches mm i

Page 7

Bulletin 74.1:ACE95JR 7Ordering GuideBody Size and Connection Styles (Select One) 1/2 NPT 1 x 1/2 NPT 1 NPT NPS 1/2 / DN 15, CL150 RF

Page 8

Bulletin 74.1:ACE95JR©Emerson Process Management Regulator Technologies, Inc., 2001, 2012; All Rights ReservedThe Emerson logo is a trademark and serv

Commentaires sur ces manuels